Arneg Perth 6 P Manuel D'installation Et De Service page 67

Table des Matières

Publicité

3
(referred to the central
riser)
A) Remove the screws
that fix the wiring
protection
plate in
place;
B) Pull out the cable;
C) Pull out the
connector;
D) Open the connector.
4
((referred to the right and left-hand risers)
This phase applies both for dismantling the right-hand
door and for preparing the left-hand riser.
A) Remove the side buffer profile using a spatula
B) Pull out the cable and open the connector..
5
Loosen the screws that fix the anti-fraying fork on the
upper part of the door. Let the fork slide and rotate it as
indicated in figure A..
6
In order to remove the door, it must be lifted
and simultaneously rotated as indicated in the
drawing so that it is first released from its
housing on the bottom part.
Given the weight of the door, the
collaboration of two workers is recommended.
Do not exert unneccessary force
05060214 00 09-2021
B
A
A
Perth 6P - Perth 6P 1E
C
B
English
D
57