Inserting The Battery / Changing The Battery B; Mode Of Operation; Temperature Measurement - Trotec TP6 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
5. Inserting the battery/Changing the battery
The infrared thermometer requires one alkaline 9V block bat-
tery of type NEDA1604, IEC 6LR61 or types of similar con-
struction for operation. If the voltage of the battery inserted is
less than the value required the LCD display
empty battery symbol "Low Bat"
this case.
Change the battery as follows: Open the battery compartment
by lifting the battery compartment cover from the grip
shown in the figure
. Exchange the battery for a new one of
the same type and close the battery compartment cover
again.
Do not leave batteries lying around as there is the risk that
they could be swallowed by children. Leaking or damaged
batteries can cause burns if contact is made with the skin.
Never try to charge batteries. Do not throw batteries in a fire.

6. Mode of operation

Infrared thermometers measure the surface temperature of an
object. The instrument sensor records the thermal radiation
that is emitted or reflected by the object, or passes through the
object, and converts this information into a temperature value.
B 05
shows the
. Change the battery in
, as
Operating manual – English

7. Temperature measurement

To measure temperatures point the opening of the IR sensor
at the object to be measured and press the temperature meas-
urement button
. The "SCAN" measurement indicator
is shown in the LCD display. Ensure that the measuring spot size
is no larger than the target. The temperature value
being determined is shown in the LCD display.
To locate the hottest point on an object the infrared thermo-
meter is pointed at a spot outside the desired area and the area
is then scanned with zigzag movements with the temperature
measurement button
found. After you have released the temperature measurement
button
the determined temperature value
for about 10 seconds. "HOLD"
After about 10 seconds the instrument shuts down by itself
to conserve the battery capacity.
When the laser is switched on, the laser beam
To activate the laser, push the laser on/off button
the device is switched on. The laser symbol
the LCD display.
The TP6 has a dual laser, which automatically displays the size
of the measurement spot.The distance between the two laser beams
corresponds to the diameter of the measuring spot.
held down until the hottest point is
is displayed
is displayed during this time.
is visible.
appears on
currently
when

Publicité

Table des Matières
loading

Table des Matières