BORETTI CFBG901AN Prescriptions De Montage Et Mode D'emploi page 238

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTION OF THE POWER SUPPLY CABLE
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A"
(fig. 9.1).
Open the cable gland by unscrewing screw "F" (fig. 9.2), unscrew the terminal
screws.
Insert the feeder cable of the suitable section (as described in the next chapter)
into the cable gland.
Connect the phase and earth cables to the terminal block according to the diagram
in figure 9.3.
Pull the feeder cable and block it with cable gland.
Close the terminal block cover (check the two hooks "A" are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws
fixing the cover plate behind the terminal block.
N.B. The earth conductor must be left about 3 cm longer than the others.
FEEDER CABLE SECTION Type "H05RR-F"
220-240 V ac
(*) – Connection possible with plug and outlet
Fig. 9.1
238
3 x 1,5 mm
2
(*)
A
F
Fig. 9.2
230 V
220-240 ac
L
N
PE
Fig. 9.3