gefran GFX4-IR PROFINET Manuel Utilisateur page 33

Masquer les pouces Voir aussi pour GFX4-IR PROFINET:
Table des Matières

Publicité

Address
Name
PS_OF_ZONE_2
+ 62.0
HB_T_ZONE_2
+ 64.0
HB_P_ZONE_2
+ 66.0
IR_00_ZONE_2
+ 68.0
IR_01_ZONE_2
+ 70.0
IR_02_ZONE_2
+ 72.0
IR_03_ZONE_2
+ 74.0
IR_04_ZONE_2
+ 76.0
IR_05_ZONE_2
+ 78.0
IR_06_ZONE_2
+ 80.0
P_ON_T_ZONE_2
+ 82.0
FU_TA_ZONE_2
+ 84.0
H_PB_ZONE_2
+ 86.0
H_IT_ZONE_2
+ 88.0
H_DT_ZONE_2
+ 90.0
HI_S_ZONE_2
+ 92.0
HI_L_ZONE_2
+ 94.0
TYP_ZONE_3
+ 96.0
PS_TA_ZONE_3
+ 98.0
AL_ZONE_3
+ 100.0
HD_2_ZONE_3
+ 102.0
HD_5_ZONE_3
+ 104.0
CTR_ZONE_3
+ 106.0
PS_TM_ZONE_3
+ 108.0
PS_OF_ZONE_3
+ 110.0
HB_T_ZONE_3
+ 112.0
HB_P_ZONE_3
+ 114.0
IR_00_ZONE_3
+ 116.0
IR_01_ZONE_3
+ 118.0
IR_02_ZONE_3
+ 120.0
IR_03_ZONE_3
+ 122.0
IR_04_ZONE_3
+ 124.0
IR_05_ZONE_3
+ 126.0
IR_06_ZONE_3
+ 128.0
P_ON_T_ZONE_3
+ 130.0
80992D_MSW_PROFINET_GFX4-IR_01-2021_FRA
Initial
Type
value
INT
2677
MINIMUM NON CONDUCTION TIME TO REACTIVATE THE PHASE
SOFTSTART RAMP (ZONE 2)
INT
2104
DELAY TIME FOR ACTIVATION OF HB ALARM (ZONE 2)
INT
2785
PERCENTAGE HB ALARM SETPOINT OF CURRENT READ IN HB
CALIBRATION (ZONE 2)
INT
2806
CT INPUT AT HB CALIBRATION PHASE 0 (FOR IR LAMPS) (ZONE 2)
INT
2807
CT INPUT AT HB CALIBRATION PHASE 1 (FOR IR LAMPS) (ZONE 2)
INT
2808
CT INPUT AT HB CALIBRATION PHASE 2 (FOR IR LAMPS) (ZONE 2)
INT
2809
CT INPUT AT HB CALIBRATION PHASE 3 (FOR IR LAMPS) (ZONE 2)
INT
2815
CT INPUT AT HB CALIBRATION PHASE 4 (FOR IR LAMPS IN PA
MODE) (ZONE 2)
INT
2816
CT INPUT AT HB CALIBRATION PHASE 5 (FOR IR LAMPS IN PA
MODE) (ZONE 2)
INT
2817
CT INPUT AT HB CALIBRATION PHASE 6 (FOR IR LAMPS IN PA
MODE) (ZONE 2)
INT
2747
SWITCHING ON MODE (ZONE 2)
INT
2755
MAXIMUM LIMIT OF RMS CURRENT IN NORMAL OPERATION
(ZONE 2)
INT
2053
PROPORTIONAL BAND FOR HEATING OR HYSTERESIS IN ON-OFF
CONTROL (ZONE 2)
INT
2055
INTEGRAL HEATING TIME (ZONE 2)
INT
2056
DERIVATIVE HEATING TIME (ZONE 2)
INT
2450
MAXIMUM LIMIT OF MAIN INPUT SCALE (ZONE 2)
INT
2191
UPPER LIMIT OF SETPOINT (ZONE 2)
INT
4496
TYPE OF PROBE, SIGNAL AND SCALE OF MAIN INPUT
(ZONE 3)
INT
4802
MAXIMUM PREAK CURRENT LIMIT DURING PHASE SOFTSTART
(ZONE 3)
INT
4291
SELECT NUMBER OF ENABLED ALARMS (ZONE 3)
INT
4756
ENABLE POWER FAULT ALARM (ZONE 3)
INT
4799
ENABLE TRIGGER MODES (ZONE 3)
INT
4276
TYPE OF CONTROL (ZONE 3)
INT
4801
DURATION OF PHASE ANGLE SOFTSTART RAMP (ZONE 3)
INT
4725
MINIMUM NON CONDUCTION TIME TO REACTIVATE THE PHASE
SOFTSTART RAMP (ZONE 3)
INT
4152
DELAY TIME FOR ACTIVATION OF HB ALARM (ZONE 3)
INT
4833
PERCENTAGE HB ALARM SETPOINT OF CURRENT READ IN HB
CALIBRATION (ZONE 3)
INT
4854
CT INPUT AT HB CALIBRATION PHASE 0 (FOR IR LAMPS) (ZONE 3)
INT
4855
CT INPUT AT HB CALIBRATION PHASE 1 (FOR IR LAMPS) (ZONE 3)
INT
4856
CT INPUT AT HB CALIBRATION PHASE 2 (FOR IR LAMPS) (ZONE 3)
INT
4857
CT INPUT AT HB CALIBRATION PHASE 3 (FOR IR LAMPS) (ZONE 3)
INT
4863
CT INPUT AT HB CALIBRATION PHASE 4 (FOR IR LAMPS IN PA
MODE) (ZONE 3)
INT
4864
CT INPUT AT HB CALIBRATION PHASE 5 (FOR IR LAMPS IN PA
MODE) (ZONE 3)
INT
4865
CT INPUT AT HB CALIBRATION PHASE 6 (FOR IR LAMPS IN PA
MODE) (ZONE 3)
INT
4795
SWITCHING ON MODE (ZONE 3)
Comment
33