gefran GFX4-IR PROFINET Manuel Utilisateur page 32

Masquer les pouces Voir aussi pour GFX4-IR PROFINET:
Table des Matières

Publicité

UDT7
Liste des adresses Modbus des paramètres utilisés dans la FB15
Address
Name
0.0
TYP_ZONE_1
+ 0.0
PS_TA_ZONE_1
+ 2.0
AL_ZONE_1
+ 4.0
HD_2_ZONE_1
+ 6.0
HD_5_ZONE_1
+ 8.0
CTR_ZONE_1
+ 10.0
PS_TM_ZONE_1
+ 12.0
PS_OF_ZONE_1
+ 14.0
HB_T_ZONE_1
+ 16.0
HB_P_ZONE_1
+ 18.0
IR_00_ZONE_1
+ 20.0
IR_01_ZONE_1
+ 22.0
IR_02_ZONE_1
+ 24.0
IR_03_ZONE_1
+ 26.0
IR_04_ZONE_1
+ 28.0
IR_05_ZONE_1
+ 30.0
IR_06_ZONE_1
+ 32.0
P_ON_T_
+ 34.0
ZONE_1
FU_TA_ZONE_1
+ 36.0
H_PB_ZONE_1
+ 38.0
H_IT_ZONE_1
+ 40.0
H_DT_ZONE_1
+ 42.0
HI_S_ZONE_1
+ 44.0
HI_L_ZONE_1
+ 46.0
TYP_ZONE_2
+ 48.0
PS_TA_ZONE_2
+ 50.0
AL_ZONE_2
+ 52.0
HD_2_ZONE_2
+ 54.0
HD_5_ZONE_2
+ 56.0
CTR_ZONE_2
+ 58.0
PS_TM_ZONE_2
+ 60.0
32
Initial
Type
value
STRUCT
INT
1424
TYPE OF PROBE, SIGNAL AND SCALE OF MAIN INPUT (ZONE 1)
INT
1730
MAXIMUM PREAK CURRENT LIMIT DURING PHASE SOFTSTART
(ZONE 1)
INT
1219
SELECT NUMBER OF ENABLED ALARMS (ZONE 1)
INT
1684
ENABLE POWER FAULT ALARM (ZONE 1)
INT
1727
ENABLE TRIGGER MODES (ZONE 1)
INT
1204
TYPE OF CONTROL (ZONE 1)
INT
1729
DURATION OF PHASE ANGLE SOFTSTART RAMP (ZONE 1)
INT
1653
MINIMUM NON CONDUCTION TIME TO REACTIVATE THE PHASE
SOFTSTART RAMP (ZONE 1)
INT
1080
DELAY TIME FOR ACTIVATION OF HB ALARM (ZONE 1)
INT
1761
PERCENTAGE HB ALARM SETPOINT OF CURRENT READ IN HB
CALIBRATION (ZONE 1)
INT
1782
CT INPUT AT HB CALIBRATION PHASE 0 (FOR IR LAMPS) (ZONE 1)
INT
1783
CT INPUT AT HB CALIBRATION PHASE 1 (FOR IR LAMPS) (ZONE 1)
INT
1784
CT INPUT AT HB CALIBRATION PHASE 2 (FOR IR LAMPS) (ZONE 1)
INT
1785
CT INPUT AT HB CALIBRATION PHASE 3 (FOR IR LAMPS) (ZONE 1)
INT
1791
CT INPUT AT HB CALIBRATION PHASE 4 (FOR IR LAMPS IN PA
MODE) (ZONE 1)
INT
1792
CT INPUT AT HB CALIBRATION PHASE 5 (FOR IR LAMPS IN PA
MODE) (ZONE 1)
INT
1793
CT INPUT AT HB CALIBRATION PHASE 6 (FOR IR LAMPS IN PA
MODE) (ZONE 1)
INT
1723
SWITCHING ON MODE (ZONE 1)
INT
1731
MAXIMUM LIMIT OF RMS CURRENT IN NORMAL OPERATION
(ZONE 1)
INT
1029
PROPORTIONAL BAND FOR HEATING OR HYSTERESIS IN ON-OFF
CONTROL (ZONE 1)
INT
1031
INTEGRAL HEATING TIME (ZONE 1)
INT
1032
DERIVATIVE HEATING TIME (ZONE 1)
INT
1426
MAXIMUM LIMIT OF MAIN INPUT SCALE (ZONE 1)
INT
1167
UPPER LIMIT OF SETPOINT (ZONE 1)
INT
2448
TYPE OF PROBE, SIGNAL AND SCALE OF MAIN INPUT
(ZONE 2)
INT
2754
MAXIMUM PREAK CURRENT LIMIT DURING PHASE SOFTSTART
(ZONE 2)
INT
2243
SELECT NUMBER OF ENABLED ALARMS (ZONE 2)
INT
2708
ENABLE POWER FAULT ALARM (ZONE 2)
INT
2751
ENABLE TRIGGER MODES (ZONE 2
INT
2228
TYPE OF CONTROL (ZONE 2)
INT
2753
DURATION OF PHASE ANGLE SOFTSTART RAMP (ZONE 2)
Comment
80992D_MSW_PROFINET_GFX4-IR_01-2021_FRA