Falcon Professional 110 Instructions D'utilisation Et D'installation page 39

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 56
Gas Connection
A gas shut off valve must be fitted be-
tween the gas supply and the con-
nection hose. The flexible hose (not
supplied with the cooker) must be in
accordance with the relevant stand-
ards. If in doubt contact, your sup-
plier.
The rear cover boxes limit the posi-
tion of the supply point. The house
gas supply needs to terminate with a
down facing connection.
The appliance connection is located
just below hotplate level at the rear of
the cooker.
The hose should be fitted so that both
inlet and outlet connections are verti-
cal so that the hose hangs down-
wards in a 'U' shape.
Because the height of the cooker can
be adjusted and each connection is
different it is difficult to give precise
dimensions. Ideally the house supply
connection should be in the shaded
area shown in the figure showing the
back of the cooker.
After completing the gas connection,
check the cooker is gas sound with a
pressure test. When checking for gas
leaks do not use washing up liquid -
this can corrode. Use a product spe-
cifically manufactured for leak detec-
tion.
Pressure testing
The gas pressure can be measured
at the injector of one of the Left Hand
hotplate burners. Remove the pan
support, burner head and cap. The in-
jector is now accessible.
See Technical data section at the
back of this book for test pressures.
Reassemble burner top, making sure
it is reassembled in the correct way
on the burner body.
Electrical Connection
This appliance must be installed by a
qualified electrician to comply with the
relevant regulations and also the local
electricity supply company require-
ments.
WARNING: THIS APPLIANCE MUST
BE EARTHED
Note
The cooker must be connected to the
correct electrical supply as stated on
the voltage label on the cooker,
through a suitable cooker control unit
incorporating a double pole switch
having a contact separation of at
least 3mm in all poles. This cooker
must not be connected to an ordinary
domestic power point.
The total electrical load of the appli-
ance is approximately 7.2kW. The ca-
ble size used should be suitable for
this load and comply with all local re-
quirements.
Access to the mains terminal is
gained by removing the electrical ter-
minal cover box on the back panel.
Connect the mains cable to the cor-
rect terminals for your electrical sup-
ply type.
Check that the links are correctly fit-
ted and that the terminal screws are
tight. Secure the mains cable using
the cable clamp.
37
Current Operated Earth Leakage
Breakers
Where the installation is protected by
a 30 milliamp sensitivity residual cur-
rent device (RCD), the combined use
of your cooker and other domestic
appliances may occasionally cause
nuisance tripping. In these instances
the cooker circuit may need to be pro-
tected by fitting 100mA device. This
work should be carried out by a quali-
fied electrician.
Hotplate
Check each burner in turn. There is a
flame safety device that stops the
flow of gas to the burner if the flame
goes out. For each burner, turn the
control knob to the large flame sym-
bol. Press in the control knob. This
lets gas through to the burner. Keep
holding the knob pressed in and
press the igniter button or light with a
match. Keep holding the control knob
pressed in for about 10 seconds.
If when you let go of the control knob
the burner goes out, the safety device
has not held in. Wait one minute then
try again this time holding the control
pressed in for slightly longer.
Grill
Open the grill compartment door.
Turn on the grill control and check
that the grill heats up.
Oven check
The clock must be set to the time of
day before the ovens will work.
See the 'The clock' section for how
to set the time of day.
English

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Classic 110Toledo 110

Table des Matières