The starting address is defined as the first channel from which the TS-7B will respond to the controller.
Please make sure that you don't have any overlapping channels in order to control each TS-7B correctly and
independently from any other fixture on the DMX data link. If two, three or more TS-7B are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the effect to the mains, the TS-7B starts running. During the Reset, the motors are
trimmed and the device is ready for use within approximately 20 seconds.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.

Stand Alone operation

In the Stand Alone mode, the TS-7B can be used without controller. You can do without a controller as the
TS-7B features a built-in microphone, which provides automatic sound control.
Disconnect the TS-7B from the controller and set all DIP-switches to Off.
Call up the internal program
In order to call up the internal program, set DIP-switches No. 9 and 10 to On.
Master/Slave-operation
Connect the master and slave-devices as desribed above and set the DIP-switches accordingly.