Elvox VIMAR SW24.T Guide Rapide Installateur page 9

Centrale de commande 24 vcc pour portails battants
Masquer les pouces Voir aussi pour VIMAR SW24.T:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
SW24.T
OFF
45
ON
OFF
51
ON
OFF
52
ON
OFF
61
ON
OFF
62
ON
OFF
63
ON
Gate travel calibration
NOTE: To perform this procedure, the gate must be stationary.
WARNING! THE SAFETY DEVICES ARE DISABLED DURING GATE TRAVEL CALIBRATION.
Fast calibration, gear motor with encoder (DIP 10 = OFF)
(slows down at 30% of its travel, opening offset of 3 s, closing offset of 6 s)
Pressing
No.
Phase
push button
1
PROG
Procedure activation
2
51
Close leaf M2
3
-
Close leaf M1
4
-
Open leaf M1
5
-
Open leaf M2
6
-
Close leaf M2
7
-
Close leaf M1
8
-
Complete cycle
9
-
End of procedure
Note: With this type of programming, the mechanical stops are necessary both when opening and closing, during programming and in normal operation.
The steps with a grey background are for a double-leaf installation, and are not carried out for a single-leaf installation.
Advanced calibration, gear motor with encoder (DIP 10 = OFF)
(slow-down and offsets programmed by the installer)
Pressing
No.
Phase
push button
1
PROG
Procedure activation
2
51
Close leaf M2
3
-
Close leaf M1
4
-
Open leaf M1
Set the slow-down point when
5
51
opening M1
Set the stopping point when
6
51
opening M1
7
-
Open leaf M2
Set the slow-down point when
8
51
opening M2
Set the stopping point when
9
51
opening M2
10 -
Close leaf M2
Set the slow-down point when
11
51
closing M2
12 -
Complete M2 closure
13 -
Close leaf M1
Set the slow-down point when
14 51
closing M1
15 -
Complete M1 closure
16 -
Open leaf M1
17 51
Setting the offset for opening
When motor M2 is operating: it indicates that the encoder is missing (not working) or motor M2 has no encoder
When motor M2 is operating: it indicates that there is an encoder (it flashes very fast, depending on the motor rotation
speed)
Step-by-step input (term. 51) not engaged
Step-by-step input (term. 51) engaged
Pedestrian input (term. 52) not engaged
Pedestrian input (term. 52) engaged
Stop contact (term. 61) open (engaged)
Stop contact (term. 61) closed (not engaged)
Closing photocell (term. 62) engaged
Closing photocell (term. 62) not engaged
Photocell or safety edge (term. 63) open (engaged)
Photocell or safety edge (term. 63) closed (not engaged)
Description
Press the programming push-button PROG for at least 3 seconds, until the PRG LED starts flash-
ing slowly, and then release it
Press push-button 51:
M2 closes at slow speed until it reaches the closed mechanical stop
M1 closes at slow speed until it reaches the closed mechanical stop
M1 closes at slow speed until it reaches the open mechanical stop
M2 closes at slow speed until it reaches the open mechanical stop
M2 closes at normal speed, slows down at 70% of its travel, and continues until it reaches the
closed mechanical stop
M1 closes at normal speed, slows down at 70% of its travel, and continues until it reaches the
closed mechanical stop
The gate performs a complete opening and closing cycle with the default slow-down distance and
offsets.
The PRG LED turns off. End of procedure
Description
Press the programming push-button PROG and hold it down; the PRG LED will start flashing
slowly; keep PROG pressed until the PRG LED flashes fast, and then release it
Press push-button 51:
M2 closes at slow speed until it reaches the closed mechanical stop
M1 closes at slow speed until it reaches the closed mechanical stop
M1 opens at normal speed
Press 51 to set the slow-down start point when opening leaf M1
Press 51 to set the fully-open point of leaf M1, or wait for the leaf to reach the open mechanical
stop
M2 opens at normal speed
Press 51 to set the slow-down start point when opening leaf M2
Press 51 to set the fully-open point of leaf M2, or wait for the leaf to reach the open mechanical
stop
M2 closes at normal speed
Press 51 to set the slow-down start point when closing leaf M2
Leaf M2 continues until it reaches the closed mechanical stop
M1 closes at normal speed
Press 51 to set the slow-down start point when closing leaf M1
Leaf M1 continues until it reaches the closed mechanical stop
Leaf M1 restarts opening at normal speed
Press 51 to set the opening offset time
EN
7

Publicité

Table des Matières
loading

Table des Matières