Specificaties - Velleman PIR1200C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. Test
• Set the selection switch (fig. 1 #2) to the "1" position.
• Switch on the power. The load shouldn't work and the indicator lamp (fig. 1 #1) should be green. It takes the
device some 5 to 10 sec. to react when movement is detected. The indicator lamp should turn red and the load
should work. When there is no new detection, the load should stop working and the indicator lamp should return to
green after 5 to 30 seconds.
• Make the detector detect again. This time the load should stop working after 5 to 15 seconds.
• Set the selection switch (fig. 1 #2) to position 2. When the ambient light is >10Lux, the PIR1200C shouldn't detect
anything. In <10Lux conditions, operating time should be 25-35 seconds.
7. Notes
• A qualified electrician should install this device.
• Do not block the detection window and make sure the detection area holds no moving objects.
• Do not install the device close to air conditioning vents, radiators, etc.
• Do not open the housing. A skilled technician should repair this device in case of malfunction.
8. Troubleshooting
Problem
The load doesn't work
Sensitivity is poor
The load doesn't switch off.
The contents of this manual are subject to modifications without prior notice.
PIR1200C -- PIR BEWEGINGSDETECTOR VOOR PLAFONDMONTAGE
1. Inleiding
De PIR1200C is een gevoelige en energiezuinige bewegingsdetector. Hij is uitgerust met een IC en gebruikt SMT
technologie. Hij kan het onderscheid maken tussen dag en nacht (drempel op 10Lux). Het toestel is zeer makkelijk te
installeren en het is geschikt voor een groot aantal toepassingen.

2. Specificaties

Voedingsbron
Omgevingslicht
Activeringsduur
Detectiehoek
Detectiebereik
Werktemperatuur
PIR1200C
Check the power supply and the load.
Check if the indicator lamp is green and turns red
Check if the ambient light isn't >10Lux (for positions 2-4)
An object may be blocking the detection window.
Check the ambient temperature.
Check if the motion is located within the boundaries of the detection range.
Check the installation height.
Check if the moving orientation is correct.
Movement is continually detected.
The activation duration is too long.
The power supply does not correspond to the specifications
Dramatic temperature changes in close vicinity to the sensor. These may be caused by
e.g. air conditioning vents or central heating elements, etc.
220-240Vac / 50-60Hz
< 10lux
min. 5sec. / max. 6min. ± 1min.
120° (muurmontage) / 360° (plafondmontage)
6m max. (24°C)
-20°C tot +40°C