Master DH 716 Manuel D'utilisation Et De Maintenance page 6

Masquer les pouces Voir aussi pour DH 716:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
6. Handle
7. Air inlet / Filters
8. Water level window
9. Water tank
►►
5. OPERATION
► Control panel FIG. 4
1. Humidity setting button
2. Working mode indicator (continuous working, humidity
40%, 50%, 60%, 70%)
3. Humidity/Temperature display
4. Timer operation indicator
5. Temperature display button
6. Ionizer or TiO2 indicator (these are optional function de-
pending on the model you purchased)
7. DRYER indicator
8. DRYER button
9. High ventilation indicator
10. Speed/Ventilation button
11. Low ventilation indicator
12. Power indicator
13. ON/OFF (power) button
14. "Full Water" indicator
15. TIMER button
16. Ionizer or TiO2 button (these are optional function de-
pending on the model you purchased)
► Ambient light features
Blue light – room humidity > 70%
Green light – room humidity 50~70%
Red light –room humidity < 50%
Red light flash – water full alarm
Operation
1. Plug the unit into a correct mains socket. (Please refer
to the rating label at the rear of the unit for correct vol-
tage/frequency.)
2. Press ON/OFF button to turn on the unit. The compres-
sor will start to work.
3. Press humidity setting button to set the working model
you need: continuous working, humidity 40%, 50%,
60% or 70%. The relative indicator will light on.
4. Press speed/ventilation button to set the ventilation
speed, high or low. The relative indicator will light on.
5. Press the TIMER button to set the operating hour you
need (1~24 hours). The display window will show the
hour(s) you set as you press the TIMER button, after
releasing it for 8 seconds around, the display window
will return to the room humidity. As the set time has
been reached, the compressor will stop working auto-
matically.
6. By pressing the "TEMP" button, the display window will
show the room temperature, after releasing the button
for 8 seconds around, the display window will return to
the room humidity.
7. DRYER function is turbo ventilation to dry the moistu-
re in the air continuously, so it could help to dry the
laundry.
8. To turn off the unit, press ON/OFF button again.
9. Pre-setting function By pressing TIMER button but wit-
hout turning on the other functions (including ON/OFF
button), you can PRE-SET the time for the machine to
work. For example, if you press the timer to '2', the unit
will work automatically after 2 hours
►►
6. DRAINAGE
While the water tank is full, the compressor will stop for
self-protection and the water full indicator will turn into red.
To move the water tank, pull it out squarely from the unit.
After empting the water tank, place the water tank into spa-
ce. Make sure it is properly positioned, in order for the 'wa-
ter full' sign to go out and your dehumidifier is operating.
Please note, in case, the water tank has not been positio-
ned well, the water full indicator will turn into red.
►►
CONTINUOUS DRAINAGE
When the dehumidifier is operated at very high humidity
levels, the water tank will require more frequent drainage.
In this situation, it may be more convenient to set the unit
up for continuous drainage with the following procedures:
1. Pull out the water tank (FIG. 5).
2. Connect the drain hole with water tube of inner diame-
ter: 11 mm. The water tube is not supplied with the unit
(FIG. 6).
3. Ensure the water will always drain away freely and the
tube will remain in right place. Note! In very cold weather
conditions, precautions should be taken to prevent the wa-
ter tube from freezing.
4. Put the water tank back to its position.
►►
7. MAINTENANCE
Always unplug the unit from the mains before carrying out
any maintenance or cleaning of the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't ever use volatile chemicals, gasoline, detergents,
chemically treated clothes, or other cleansing solutions.
These all could possibly hurt the cabinet.
CLEANING THE FILTER
This dehumidifier is equipped with 2 filters (FIG. 7):
1. ANTI-DUST FILTER
Extract the filter holder, remove the active carbon filter.
Use a vacuum cleaner or tap the filter lightly for easy clea-
ning. If the filter is particularly dirty, use warm water with
a small amount of a small amount of medium strength
detergent.
Make sure the filter is completely dry before replacing.
Do not expose the filter to sunlight.
2. ACTIVE CARBON FITLER (for capturing the particles
of dust suspended in the air and preventing the produc-
tion of bacteria.)
The active carbon filter placed under the anti-dust filter is
not washable. Its life span is variable and depends on the
ambient conditions where the unit is used. The filter should
be checked periodically and replaced if necessary.
STORAGE
If not use the unit for an extended period of time. Please:
Turing the unit off, unplug and tidy AC cord.
► Completely empty the water tank and wipe it clean.
► Cover the unit and store where it will not receive direct
sunlight.
►►
8. TROUBLE SHOOTING
THE UNIT DOES NOT OPERATE:
► Is the unit plugged in?
en
CZ
DE
DK
EE
ES
FI
FR
GB
HR
HU
IT
LT
LV
NL
NO
PL
RO
RU
SE
SI
SK
UA
SE
SI
SK
TR
UA

Publicité

Table des Matières
loading

Table des Matières