Installation Instructions – ClearPath Bollard
Included:
1 Foundation Template
●
1 Bollard Housing
●
1 Bollard Cover
●
1 Tamper resistant bollard cover Mounting Screw
●
1 Bollard Base
●
2 Mounting Brackets
●
4 Socket Head Cap Screws
●
4 Flat Washers
●
4 Nylon insert Locking Nuts
●
1 Gap Pad
●
#8 Self-tapping ground screw (green)
●
Tools required:
Plumb bob or level, torque wrench for the following drive
sizes:
5/16" Hex drive (Allen) torque wrench,
1/4" Socket
T27 Center pin reject Torx drive.
Installation
S
tep 1
Prepare the foundation.
There are 3 templates provided in CPBANCHOR
kit (sold separately). From the 3 foundation
templates: CLP0012385H01AS, CLP0012385H01AD,
CLP0012385H01SY, choose the one which matches the
optical distribution you will install. Use the template to
locate the foundation bolts such that the light output is
in the desired direction(s). Install foundation anchors and
conduit.
Step 2 Prepare the bollard.
Use a center pin reject Torx drive to remove the screw on
the front of the luminaire. Next remove the cover by sliding
it first towards the top of the luminaire, then away from the
other half. Set it aside in a safe place. Loosen, but do not
remove, the four socket head cap screws with a (5/16") hex
(Allen) wrench.
2
Cooper Lighting Solutions
IB516115EN
Installation Instructions
Figure 1.
Housing Side
Cover Side
Figure 1a.
Outer Dimension Of
Bollard 4.7" X 6.3"
HOUSING SIDE
COVER SIDE
Clearpath Bollard
Anchor Bolt Template
CLP0012385H01 W/
3/8" Dia Anchor Bolts
Figure 1b. Asymmetric Double Side (CLP0012385H01AD)
Outer Dimension Of
Bollard 4.7" X 6.3"
HOUSING SIDE
COVER SIDE
Clearpath Bollard
Anchor Bolt Template
CLP0012385H01 W/
3/8" Dia Anchor Bolts
Figure 1c. Asymmetric Single Side (CLP0012385H01AS)
Outer Dimension Of
Bollard 4.7" X 6.3"
HOUSING SIDE
COVER SIDE
Clearpath Bollard
Anchor Bolt Template
CLP0012385H01 W/
3/8" Dia Anchor Bolts
Figure 1d. Symmetric Double Side (CLP0012385H01SY)
Bolt Projection
Notes: Conduit Must
Be Inside Of Opening
With A Height Of 3"
Max. Above Concrete.
Anchor Bolt Projection To
Be 1" Above Concrete.
Tolerance ± 1/8"
Notes: Conduit Must
Be Inside Of Opening
With A Height Of 3"
Max. Above Concrete.
Anchor Bolt Projection To
Be 1" Above Concrete.
Tolerance ± 1/8"
Notes: Conduit Must
Be Inside Of Opening
With A Height Of 3"
Max. Above Concrete.
Anchor Bolt Projection To
Be 1" Above Concrete.
Tolerance ± 1/8"