CHIMNEY CAP: DISTANCES AND POSITIONING UNI 10683/98
Roof slope
15°
30°
45°
60°
6.

CONNECTION TO THE FLUE

The connection to the flue (exhaust channel or pipe fitting) must be made using rigid pipes in aluminium plated steel
with minimum thickness of 2 mm or in 316 stainless steel with minimum thickness of 1 mm.
It is prohibited to use flexible metal pipes or asbestos cement pipes because they are subject to splitting or
breakage, which can lead to fume leakage, jeopardising the safety of the connection itself.
The exhaust venting pipe must be hermetically fixed to the chimney and can have a maximum inclination of 45° ; this
is to prevent excessive condensate deposits produced in the initial lighting phase and/or excessive settling of soot,
and also prevents the slowing of the vented fumes.
6097811 Rev.04 – EN
(1) In the case of adjacent flues, one chimney cap must rise above
the other by at least 50 cm to prevent the transfer of pressure
between the flues.
(1) The chimney cap must not have any obstacles within 10 m from
walls, pitch, and trees. In such case, it must be raised at least 1 m
above the obstacles.
The chimney cap must rise above the roof ridge by at least 1 m.
>A
min. H
(1)Ridge axis
colmo
¡
Distance between roof ridge and
chimney
A (m)
< 1,85 m
> 1,85 m
< 1,50 m
> 1,50 m
< 1,30 m
> 1,30 m
< 1,20 m
> 1,20 m
> _ A
0.5 m
(2)Roof
Minimum height of chimney
(measured from the outlet )
0.50 m above the ridge
1.00 m from roof
0.50 m above the ridge
1.30 m from roof
0.50 m above the ridge
2.00 m from roof
0.50 m above the ridge
2.60 m from roof
Picture 10
Picture 11
Picture 12
H (m)