draught. The flue must be adequately distanced from flammable or combustible materials by means of
insulation or an air gap.
It is forbidden to run it inside the piping of air feed systems or channels. It is also prohibited to make moving or fixed
openings on the flue for the connection of other different devices.
(1)
(2)
(3)
(4)
Max.
A+1/2A
A+1/2A
(1) Door
for
cleaning

5.1. CHIMNEY CAP

The flue draught also depends on the suitability of the chimney cap.
It is therefore indispensable that the outlet cross-section be twice the internal cross-section of the flue when making
the chimney cap by hand. As it will always rise above the roof ridge, the chimney cap must also ensure exhaust even
in the presence of wind. (see Picture 9)
The chimney cap must meet the following requirements:
The internal cross-section must be equivalent to that of the chimney.
The useful outlet cross-section must be twice that of the internal cross-section of the flue.
It must be constructed in such a way as to impede the penetration of rain, snow, or any foreign body into the flue.
It must be easy to inspect for any maintenance and cleaning operations.
Industrial chimney
(1)
cap with prefabricated
elements; permits
excellent fume
discharge
24
1) Flue in AISI 316 steel with double chamber insulated with material resistant up to
400° C. Efficiency 100% excellent.
2) Flue in refractory material with double insulated chamber and external covering in
lightened concrete. Efficiency 100% excellent.
3) Traditional flue in clay, square cross-section, with air gaps. Efficiency 80%
excellent.
4) Avoid using flues with rectangular section having a ratio different from that shown in
A
the drawing (MAX=A+1/2A). Efficiency 40% mediocre.
YES
(2) Illustration
of
a
correct
flue
with
sealed
door
for
collecting
and removing
solid
unburnt
materials.
Picture 7
.
(2) Hand made
chimney cap. The
right outlet cross-
section must be at
least twice the
internal cross-
section of the flue,
ideally 2.5 times.
Focolare 80 Idro Crystal - DSA
Picture 6
NO
(1)
Connecting
the flue to more
than
appliance is not
recommended.
Each one should
have
its
flue.
Picture 8
(3) Chimney cap for flue in
steel with internal fume
deflector cone.
Picture 9
6097811 Rev.04 – EN