ACCESSORY/REPLACEMENT ITEMS

The following items can be purchased separately as accessories or replacement items for your 7314 Series DeVilbiss Suction Unit:
Description
6' patient tubing
Collection Container Kit (Filter cartridge, 800 ml container, 4
800 ml disposable container with filter cartridge and 4
Filter cartridge (12 pack) (For Disposable Container)
Collection Container Kit (1200 ml reusable container, bacteria filter, elbow, 4
1200 ml reusable container (bacteria filter, elbow, 4
Bacteria filter (non-sterile) (12 pack) (For Reusable Container)
Carrying case
NOTE– The use of electrical cables and accessories other than those specified in this manual or referenced documents may result in increased electromagnetic emissions
from the product or decreased electromagnetic immunity of the product.
SET-UP & OPERATION
1
2
Fully charge battery for 10-17
Insert container into holder.
hOURs. (7314P series only)
NOTE–Inspect suction tubing and container for leaks, cracks, etc. and assure that all connections are secure and without leaks before using.
6A
6b
7314P - Select desired power
7314D series (non-battery
source. (Skip steps 6B if using
label)
internal battery power.)
NOTE– The 7314D series is not factory equipped with an
internal rechargeable battery. 7314P series is factory equipped
with an internal rechargeable battery and all information
regarding battery operation in this guide is applicable.
11
wARNING
If the unit is not receiving power from an external source or the battery was not recharged, the low battery indicator light will remain
on and the performance of the unit will drop off rapidly. Switch to another power source immediately after the low battery light appears
to avoid an interrupted suction procedure.
NOTE– Gauge is for reference only. If the unit sustains a severe drop, accuracy of the gauge must be checked.
CAUTION– When automatic float shut-off is activated, contents of the collection container should be emptied. Further suctioning could cause
damage to the vacuum pump.
CAUTION– Should fluid be aspirated back into the unit, equipment provider servicing is necessary as possible vacuum pump damage may
Verify suction level.
result.
NOTE - Always verify suction
level before beginning by
occluding open end of patient
tubing while observing gauge.
Adjust knob to desired level.
EN - 4
" and 6' tubing package)
3/8
3/8
" tubing (48 each)
3/8
" tubing)
" tubing) (6 pack)
3/8
3A
Disposable Container
Connection: Attach 43/8"
tubing from filter cartridge to
tubing connector on unit.
7
If using AC or DC power, plug
the small connector into the
DC power input on the side of
unit.
Part No. Description
6305D-611 12V DC power cord (1 each)
7305D-633 AC to DC adapter/charger (see Specifications for
manufacturer information)
7305D-632 Power cord for US
7305D-635 Power cord for Continental Europe
7314D-603 Power cord for UK
7314D-604 Power cord for Australia
7305D-608 Power cord for Japan
7314D-606
3b
4
Reusable Container
Attach 6' patient tubing to
Connection: Ensure that the
container lid at outlet labeled
clear side of the bacteria filter
<Patient>.
is toward elbow and bottle
when installing. Do not reverse
direction of filter. The bacteria
filter should then be connected
to the 90˚ elbow connection,
and the elbow should be
connected to the top of the
container lid where it says
<Vacuum>.
8
9
Plug the other end into an AC
Turn the unit
wall outlet or DC receptacle.
NOTE– The AC adapter may
become warm to the touch
during charging or running of
the unit. This is normal.
Part No.
7304D-619
7314P-613
DV51D-606
DV51D-607
DV51D-608
DV51D-609
DV51D-613
5
Ensure power switch is
10
Adjust the suction level.
"on".
A-7314
"off".