Specifications
General Specifications
Maximum voltage applied to any terminal :
1000V
or 1000V
rms
DC
AC
Display : 50,000 counts, over range to 110%.
Polarity Indication :
Automatic, positive implied, negative indicated.
Over Range Indication : OL
Measuring Rate : 10 samples per second
Power Requirements : 4 x 1.5V IEC LR6 or AA size
Battery Life: 100 hours
Low Battery Indication : "
batteries voltage drops below operating voltage.
Low Battery Voltage: Approx 4.5V
Auto Power Off: Default 20 minutes.
Operating Ambient : -10°C to 30°C (< 85% RH),
30°C to 40°C (< 75% RH),
40°C to 50°C (< 45% RH)
Storage Temperature :
-20°C to 60°C, 0% RH to 80% RH (batteries not fitted)
Temperature Coefficient :
0.1 x (Specified Accuracy) / °C, < 18°C or > 28°C
Operating Altitude : 6561.7ft (2000m)
Calibration Cycle : 1 time per year
Weight : 630g including battery.
Dimensions (W x H x D) : 95 x 207 x 52 (mm) with holster.
Accessories :
Batteries, test leads, user manual & software CD.
Safety : Complies with EN 61010-1, EN 61010-2-030
CAT IV 600V, CAT III 1000V
The circuits not connected to mains.
Ⅰ
The circuits directly connected to Low-voltage
Ⅱ
installation.
The building installation.
Ⅲ
The source of the Low-voltage installation.
Ⅳ
EMC : EN 61326-1, EN 61326-2, EN 55011, EN 61000-4
Pollution Degree : 2
Shock Vibration : 5Hz to 55Hz, 3g max
Sinusoidal vibration for MIL-PRE-28800F class 2.
Drop Protection : 5ft (1.5m)
Indoor Use
" is displayed when the
17