3. Specifications
Electrical data
Power supply U
B
Influence of power supply
Permissible residual ripple
Output signal, variant I
Permissible max. load R A
Effect of load
Output signal, variant II
Impedance at voltage output
Load capacity at voltage output
Sensor sampling rate
Linearity
Output signal accuracy
Resolution
Refresh rate (measuring rate)
Input signal, angle of rotation
Long-term stability of electronics < 0.3 % of FS/a
Temperature error, electronics
Warm-up time
Permissible ambient temperature 0 ... 40 °C
Permissible storage temperature
Electromagnetic compatibility
(EMC)
Electrical connection
Ingress protection
WIKA operating instructions model TGT73
DC 12 ≤ U B ≤ 30 V
≤ 0.1 % of full scale value/10 V
≤ 10 % ss
4 ... 20 mA, 2-wire, passive, per NAMUR NE43
R A ≤ (U B - 12 V)/0.02 A with R A in Ω and U B
in V, however max. 600 Ω
≤ 0.1 % of FS
0 ... 10 V
0.5 Ω
2 ... 100 kΩ
600 ms
≤ 1.0 % of span (limit point setting)
0.2 % of FS (electronics only)
0.15 % of FS (10 bit resolution at 360°)
> 1/s
0 ... 270 ∢ °
< 0.3 % of FS/10 K (in overall temperature
range)
≤ 5 min
-40 ... +70 °C without liquid damping
-20 ... +70 °C with liquid damping
EMC directive 2004/108/EC, EN 61326
emission (group 1, class B) and interference
immunity (industrial application)
via angular connector, 180°
rotatable, max. 1,5 mm², cable
protection, M20 x 1.5 cable gland,
cable outer diameter 7 ... 13 mm,
incl. strain relief
IP 65 to IEC 60529
Protection against reverse polarity and
overvoltage
GB
9