Installing the cooling unit
No. in fig. j,
page 9 and
fig. k, page 10
1
2
3
4
Caution!
a
Carefully insulate and seal off the wall openings after installation to
prevent moisture penetration.
For cooling units with valve couplings
➤ Cut out a hole with a diameter of at least 30 mm (fig. d, page 7) for the
cooling lines. To do this, use a circular cutter.
Caution!
a
Never bend the connecting line between the vaporiser and the unit.
The minimum bending radius is 25 mm.
6.2
Installing the cooling unit
It is important to select the proper location for setting up the unit. To ensure
trouble-free operation, please note the following points:
Set up the cooling unit in a dry, sheltered place. Avoid placing it near heat
sources such as radiators, gas ovens or hot water pipes. Do not place in
direct sunlight.
On a boat, install the cooling unit, if possible, below the waterline.
The heated air must dissipate unhindered (fig. e, page 8).
When installing the cooling unit in a closed room such as a wardrobe,
pantry or aft compartment, openings must have a cross section of at
least 200 cm² (25 cm x 8 cm) for cooling and exhaust air.
Make sure that the air flow on the condenser (fig. e 3, page 8) is not
restricted.
Maintain a minimum distance between the condenser and adjoining wall
of 50 mm.
CS-NC15: Observe the drilling template (fig. l, page 11) and the
installation drawing (fig. m, page 12).