42
WATER DRAIN CONNECTION
A
TECHNICAL INFORMATION
Dimensions
Electrical connection
Water supply pressure
Water supply
Capacity
1) Connect the water inlet hose to a water tap with a 3/4'' thread.
2) If the hot water comes from alternative sources of energy, (e.g. solar panels, aeolian
energy), use the hot water supply to decrease energy consumption.
max. 850 mm
max.
4000 mm
min. 400 mm
Width / Height / Depth (mm)
Refer to the rating plate.
Min. / max. (bar / MPa)
1)
Cold water or hot water
Place settings
Connect the water drain hose to:
• The sink spigot. Attach the water
drain hose under the kitchen counter.
This prevents that waste water from
the sink goes back to the appliance.
• A stand pipe with vent-hole. The in-
ternal diameter must be minimum 40
mm.
Remove the sink plug when the appli-
ance drains. This prevents water to go
back to the appliance.
An extension hose for the water drain
hose must be shorter than 2 m and with
the same diameter as the water drain
hose.
If you connect the water drain hose to a
trap spigot under the sink, remove the
plastic membrane (A). A not complete
removal of the membrane causes a
blockage in the spigot and problems
with drain.
The appliance has a non-return valve
that prevents dirty water to go back to
the appliance. If there is a non-return
valve in the sink spigot, remove it to
prevent the appliance to drain incor-
rectly.
2)
596 / 850 / 610
(0.5 / 0.05 ) / (8 / 0.8 )
max. 60 °C
12