Anleitung_KH_1500_SPK7__ 04.03.14 10:35 Seite 9
Danger!
Read all safety regulations and instructions. Any
errors made in following the safety regulations and
instructions may result in an electric shock, fire and/or
serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout (Fig. 1, 3)
1
Air outlet grille
2
Indicator light
3
Heat output switch
3. Items supplied
Open the packaging and take out the equipment
n
with care.
Remove the packaging material and any
n
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
n
Inspect the equipment and accessories for
n
transport damage.
If possible, please keep the packaging until the
n
end of the guarantee period.
Danger!
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
Fan Heater
n
Original Operating Instructions
n
4. Intended use
The equipment is designed exclusively for use as an
additional heater in dry, closed rooms. It is designed
to be operated only when placed on the floor.
The equipment may only be used for the tasks it is
designed to handle. Any other use is deemed to be a
case of misuse. The user/operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications.
Our warranty will be voided if the equipment is used in
commercial, trade or industrial businesses or for
equivalent purposes.
5. Technical data
Rated voltage:
Heat output:
Protection class:
Equipment dimensions: approx.:
6. Before starting the equipment
The equipment can be used indoors in a free
standing position. Keep a minimum distance of 1 m
between the housing and walls, combustible
materials (furniture, curtains, etc.). The equipment
may only be used completely mounted and standing
vertically on a stable surface. It is prohibited to
operate the equipment on an instable surface (e.g. on
a bed).
Important. Before using the equipment for the first
time, check that the voltage supply is the same as the
voltage details set out on the rating plate.
Read the safety regulations in section 1.
When the equipment is used for the first time or after
a long period of rest it may emit an odor for a short
time. This is not a fault.
Check the correct air throughput by holding a sheet of
paper a distance of 10 cm in front of the air outlet
grille. The paper must be blown away from the air
outlet grille.
7. Operation
7.1 Topple cut-out
If the equipment topples during operation, it is
automatically turned off by the switch (Fig. 2/Item 4).
When the heater is placed upright again (the switch
(Fig.2/Item 4) must be activated), the equipment
restarts immediately.
GB
220-240 V ~ 50 Hz
1500 W (750 W)
II /
17 x 10 x 22 cm
9