Shelf life
The equipment has a shelf life of 5 years from the date
of manufacture. However, note that the battery must
be charged at least once a year.
Temperature range
• Storage temperature. Fig. 3.
• Service temperature. Fig. 4.
3. Use
3.1 Unpacking
Check that the equipment is complete in accordance
with the packing list and has not been damaged in
transit.
3.2 Packing list
Fig. 1.
No. Part
1. Fan SR 700, bare
2. Battery SR 701, 2,2 Ah
3. Battery charger SR 713
4. Belt PES SR 508
5. Particle filter SR 510 P3 R, 2x
6. Filter adapter
7. Pre-filter SR 221, 10x
8. Pre-filter holder
9. Flow meter SR 356
10. User instructions
11. Cleaning tissue SR 5226
12. Plug kit
3.3 Accessories
Fig. 2.
No. Part
1.
Hood SR 561
2.
Hood SR 562
3.
Hood SR 520 M/L
3.
Hood SR 520 S/M
4.
Hood SR 530
5.
Face shield SR 540
6.
Face shield SR 570
7.
Full face mask SR 200, PC-visor
7.
Full face mask SR 200, glass visor
8.
Half mask SR 900 S
8.
Half mask SR 900 M
8.
Half mask SR 900 L
9.
Welding shield SR 590
10. Hose SR 550
10. Hose SR 551
11. Hose SR 951
12. Twin hose SR 952
13. Helmet with Visor SR 580
14. Steel net disc SR 336
15. Storage bag SR 505
16. Leather belt SR 503
17. Rubber belt SR 504
18. Gasket to fan
19.
Harness SR 552
20. Particle lfilter P3 R, SR 710
3.4 Filters
Read carefully the user instructions accompanying the
filters.
Particle filter
The fan unit may be used with only particle filters P3 R
(PAPR-P3), model number SR 510 with filter adapter
or SR 710, which provides protection against all types
of particles, both solid and liquid.
Note!
• When filters are changed, both filters must be
changed at the same time.
Pre-filter
The pre-filters SR 221 protect the main filter against
excessively fast clogging. The pre-filter holders also
protect the main filters against handling damage.
3.5 Assembly
a) Battery
• Remove and charge the battery. Fig. 5, 6, 7.
The charger carries out charging automatically in
three stages. Fig. 8.
1. Orange LED.
2. Yellow LED.
3. Green LED.
• Put the battery back. Fig. 9.
Warning!
• Always recharge the battery before it has become
fully discharged.
• The charger may be used only for charging the
batteries for the SR 700.
• The battery may be charged only with a genuine
Sundström charger.
• The charger is designed only for use indoors.
• The charger must not be covered while it is in use.
• The charger must be protected against moisture.
• Never short circuit the battery.
• Never try to dismantle the battery.
• Never expose the battery to a naked flame. There is
Ordering No.
risk of explosion/fire.
H06-5012
H06-5112
b) Belt
H06-0212
• Assemble the belt. Fig. 10, 11, 12.
H06-0312
Note!
H06-0412
Study the illustrations carefully to ensure that the belt
H06-0512
will not end up upside down or back to front.
H06-6512
H01-1212
c) Breathing hose
H01-1312
Read carefully the user instructions accompanying the
H01-3012
head top.
H01-3112
Full face mask SR 200
H01-3212
• Assemble the hose between Full face mask SR 200
H06-4012
and particle filter fan unit SR 700. Fig. 13, 14, 15.
T01-1216
• Check that the hose is firmly secured.
T01-1218
T01-3003
Half mask SR 900:
R01-3009
• Assemble the hose between half mask SR 900 and
H06-8012
particle filter fan unit SR 700. Fig. 16, 17.
T01-2001
• Check that the hose is firmly secured.
T06-0102
T06-0103
T06-0104
d) Particle filters
R06-0107
Two filters must always be used at the same time.
T06-0116
• Check that the gaskets in the filter mounting of the
H02-1512
fan unit are in place and are in good condition.
Fig. 18.
• If particle filter SR 510 are used, snap it on the filter
adapter without pressing onto the centre of the
filter.
• Screw the filter into the filter mounting so far that
the adapter will be in contact with the gasket. Then
turn it about 1/8 of a turn further in order to ensure
a good seal. Fig. 19.