Optional Free Chlorine control
Metering and control in ppm of
the free chlorine of the water.
1
2
3
4
Free Chlorine probe
3
red
4
black
Chlorine probe detector
FL2
(rotameter)
3
black
brown
5
blue
6
Optional Conductivity probe
Metering and control of
the conductivity of the
water in Msiemens.
Conductivity probe
yellow
1
transparent
2
Optional Temperature
Temperature probe
necessary to activate
the filtration modes:
Temperature
probe
heating, intelligent,
smart.
1
red
yellow
2
3
black
110-230 V
DRY CONTACT
max. 3.15 A
1 2 3 4 5 6
7 8 9
10 11 12 13 14
Setup and connection of a Variable Speed
Pump, see section 13 - Variable Speed Pump
4.3 MEASURES / Free Chlorine calibration
4.14
4.17
1
2
3
4
5
6
7
8
4.4 MEASURES / Conductivity calibration
4.22
1
2
4.5 MEASURES / Temperature calibration
4.27
1 2 3
5. FILTRATION / Manual mode
N
L
A1 A2
14
11
12
FILTER PUMP
&
Filtration control
7
8
4.16
4.15
4.14 Calibration of the Free Chlorine probe:
Recommended every month during usage season.
4.15 Calibration with buffer (photometer DPD1): Follow
the instructions in 6 steps that appear in the display.
4.16 Step 1 of 6 - Calibrate Cl at 0 ppm (offset): Close
the water flow through the probe and wait until the
reading is less than 0,10 ppm. Wait between 5 to 60
min. Press OK when the reading is close to 0.
4.17 Step 3 of 6 - Calibrate Cl: Open the water flow
4.18
4.19
until achieving 80-100 liters/hour. Wait until obtaining
a stable reading of ppm. Wait between 5 to 20 min.
Press OK when the reading is stable.
4.18 Step 5 of 6 - Establish the real ppm values
with the plus/minus keys according to your analysis
result of DPD1 (free chlorine).
4.19 Step 6 of 6 - If this screen is not shown repeat
the calibration process.
4.20
4.21
4.21 Manual calibration: Open de water flow and
set the flowmeter (rotameter) at the right level of
flow (80-100l/h). Wait some minutes until the current
level is stable. With the plus/minus keys, insert
manually the water chlorine level (use a manual
DPD1 test kit). Press OK when the DPD1 value is
correct on display (target measurement).
4.23
4.24
4.22 Calibration of the Conductivity probe:
Recommended every month during usage season.
4.23 Calibration with buffer (buffer solution 1413 µS/
12880 µS/ neutro): Follow the instructions in 7 steps
that appear in the display (screen 4.24 corresponds
to step 1).
4.25
4.26
4.25 Manual calibration: Allows to adjust the probes
at 1 point (without buffers) – only recommended to
adjust small deviation in the readings.
4.26 Without removing the probe from the water,
use the plus/minus keys to adjust the reading so it
matches with your reference value (photometer or
other measurement).
4.28
4.28 Temperature calibration: To set difference
between the measured value of the probe and the
actual temperature, use the plus/minus and up/down
keys. Set to the actual temperature of the probe and
press OK.
5.1
5.2
5.1 Filtration:
Configuration control of the filter pump. To set, select
Filtration and confirm by pressing OK . The mode
selection is done in Mode line with the plus/minus keys.
5.2 Manual:
Manually turns ON/OFF the filtration process. No timing
or additional functions. The State line indicates whether
the filtration pump is ON.
See section Filter Cleaning below.
13