Hayward AquaRite UV LS Guide De L'utilisateur page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
For complete technical information of your device, access the following link: www.smartswim.net
Conductivity probe
1
yellow
2
transparent
Cover
1
&
5
Chlorine probe
detector
FL2
(rotameter)
black
3
5
brown
blue
6
Flow switch
FL1
2
&
5
Acid deposit
level
TANK
4
&
5
Temperature probe
1
red
yellow
2
3
black
Ionization
&
7
8
(according to model)
pH
AUX 1
pH Control
Ultraviolet
1
&
2
Heating ON/OFF
Status of the auxiliar relays
Current time
Hydrolysis / Electrolysis
Production intensity in % (hydrolysis)
and gr/h (electrolysis)
Cu/Ag Ionization
(according to model)
Intensity en mA
Automatic measurements: pH/redoX/
free chlorine/conductivity
(according to options)
State filtration relay
(see section 5- Filtration)
man
Manual
aut
Automatic
hea
Heating
Smart
smt
Intelligent
int
Boost
bst
Communication display – mother board
PLUS key
Modify value/selection
GENERAL INSTALLATION GUIDE
DOMESTIC & INDUSTRIAL DEVICES
1. ELECTRONIC BOX ELECTRICAL CONNECTIONS
1
110-230V max. 3.15A Ground
2
1 2 3 4 5 6 7 8 9
1
2
3
4
5
6
7
8
1 2 3
Ground
AUX 2
redoX / free chlorine
&
3
4
ppm's (pump)
&
5
6
Ultraviolet ON/OFF
(according to model)
red indicates communication error
MINUS key
OK key
Modify value/selection
Select/confirm
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
DRY CONTACT
10 11 12 13 14 15 16
Free Chlorine
3
red
4
N
L
A1
A2
14
11
12
FILTER PUMP
LIGHT
Filtration control
Lighting control
11
&
12
9
&
10
2. MAIN SCREEN
Cover
Pol 1
Flow
Low
Pr on
Pol 1
ON/OFF
ON/OFF
TANK
State relay lighting
Manual /
man
aut
UP key
Navigation up
11
1 2 3 4
1
2
3
4
1
1
1
2
2
2
3
3
3
4
4
4
redoX
pH
black
AUX 3
AUX 4
Heating control
13
&
14
15
&
Water temperature
Production automatically reduced to
the % selected
(see display 3.6)
Polarity 1 /
Polarity 2
Pol 2
Waiting time
---
Filtration stopped due to lack of water flow
Lack of conductivity or salt / low water temperature /
scale on cell / exhausted cell
(check working hours)
Ionizer timer
Polarity 1 /
Pol 2
Polarity 2
7.5
Setpoint pH maximum (acid control)
Function of acid pump and base pump
Maximum dosing time exceeded
AL3
7.0
Setpoint pH minimum (base control)
Function of chlorine pump
Flow alarm
FL 1
700
Setpoint redoX minimum
Maximum dosing time exceeded
AL3
1.00
Setpoint Free Chlorine minimum
FL 1
Flow alarm /
Error rotameter Cl
FL 2
AL3
Maximum dosing time exceeded
Low level chemical tank
Automatic
DOWN key
Navigation down
Variable speed pump
1
slow
2
medium
3
fast
4
common
Device control SLAVE
brown
blue
1
2
Connection remote display*
red
yellow
1
2
3
green
4
black
Connection WIFI module
1
red
2
yellow
3
green
4
black
*I n case of connecting 2
display´s on the device,
remember not to connect
the remote display in this
communication channel.
Use the "EXTERN" channel
instead.
16
(
to reset the alarm)
(
to reset the alarm)
2
(
to reset the alarm)
RETURN/ESCAPE key

Publicité

Table des Matières
loading

Table des Matières