TIMER SETTING PROCEDURE.
Press the 1 HR TIMER button. The 1-HOUR ON TIMER mark
will appear on the display .
1-HOUR TIMER cancellation procedure.
• Press the ON/OFF button to turn the air conditioner off.
• Wait for the indoor unit to stop operating.
• Press the ON/OFF button again to turn the air conditioner on.
DISPLAY AFTER THE SETTING OPERATION
NOTES
If the 1-HOUR TIMER button is pressed after a certain time
is elapsed from the setting operation, the 1-HOUR timer
function is activated again.
COMBINING THE 1-HOUR TIMER AND THE DAILY PROGRAM
The 1-hour timer can be activated after the daily program
setting (par. C).
If the 1-HR TIME is pressed with the TIMER set in OFF
(
sign on the display) this setting will be cancelled as
the 1-HOUR TIMER is activated, the air conditioner runs for
1 hour and then it stops.

ADJUSTING THE AIR FLOW DIRECTION

HORIZONTAL (manual)
The horizontal air flow can be adjusted by moving the vertical
vanes to the left or right, as indicated in the following figures.
VERTICAL (with remote control unit)
Make sure that the remote control unit has been turned on. Press
the FLAP button to select the sweep function or to choose one of
the six positions of the flap.
CAUTION
Set vertical vanes to the front position during COOLING/DRY
operation if humidity is high.
If the vertical vanes are set to the left-most or right-most
position, condensation will form around the air outlet and
drip off.
CAUTION
Do not move the flap with your hands when the air conditioner
is running.
Left
Vertical vane
Air outlet
grille
COOL and DRY
Sweep function
The flap starts moving up and down to deliver air
over the sweep range.
Setting the Airflow Manually
Referring to the above illustration, use the FLAP button
to set the airflow direction within the range used during
the heating, cooling, or dehumidifying operation
NOTES
• Use the FLAP button on the remote control to adjust
the position of the flap. If you move the flap by hand,
the factual flap position and the flap position on the
remote control may no longer match. If this should
happen, shut off the unit, wait for the flap to close,
and then turn on the unit again; the flap position will
now be normal again.
• Do not have the flap pointed down during cooling
operation. Condensation may begin to form around the
air vent and drip down.
OPERATION WITHOUT THE REMOTE
CONTROL UNIT
If you have lost the remote control unit or it has troubles, follow
the steps below.
1. WHEN THE AIR CONDITIONER IS STOPPED
If you want to turn on the air conditioner, switch the operation
selector to the OFF position, and then to the ON position.
Right
NOTE
The set temperature, and fan speed are automatically set at
the last selection before stopping.
9
Up
Flap
Down
6
5
SWEEP
4
3
2
1
SWEEP
HEAT
• The flap automatically closes when the unit is off.
• During the heating operation, the fan speed
will be very low and the flap will be in the
horizontal position (position 6 ) until the air
being blown out of the unit begins to warm.
Once the air warms up, the flap position and
fan speed change to the settings specified
with the remote control.
CAUTION
EG