Counter clockwise rotation
Operating pressure setpoint is lowered
Secure the set screw with the locknut after setting the desired operating pressure setpoint.
The change of the set point per revolution of the screw is to be taken either from the table or from the
setting diagram.
When using manometers in the plant system, it is recommended to set the combined pressure
regulator with the help of the manometer. If the system does not offer this option, the operating
pressure setpoint can be set on the basis of the setting diagrams.
6.1
Setting diagram 4182-1 / 4186-1
Change in the operating pressure per
Operating instructions
6 to 24 bar
1 to 12 bar
Operating pressure ranges
Preset operating pressure
revolution
herose.com
16 to 38 bar
1-12 bar
6-24 bar
8 bar
12 bar
1.2 bar/n
2 bar/n
Revolutions (n)
16-38 bar
20 bar
3 bar/n
23