Important Instructions
•
As the surfaces of the heater cabinet get hot in
use, flammable or other objects presenting a dan-
ger of fire must not be placed on, or near the heat-
er.
Do not, therefore, place any wooden objects,
clothes or washing, newspapers, blankets or the
like on or over the heater and do not put any piec-
es of furniture made of inflammable materials, nor
spray tubes or similar objects closer than
25cm in front of, or on the heater, especially not in
front of the air-outlet grille.
•
It is important to remember that the surfaces of
the heater can reach temperatures in excess of
80°C during operation.
•
The storage heater is only to be used in rooms
where neither explosive gases (e.g. from floor-
sealant), nor inflammable dust is present!
If renovation work causing dust accumulations is
taking place the heaters must either be operated
without the fans or switched off altogether.
•
Electrical appliances conform to valid safety regu-
lations. Repairs and service to electrical appliances
must only be carried out by a competent electri-
cian. Improper repair can mean distinct danger to
the user.
•
This heater is not intended for operating by per-
sons (including children), with reduced physical,
sensory or mental abilities or for lack of experience
and/or for lack of knowledge to be used it by a per-
son responsible for their security is supervised or
received from instructions like the heater to use.
Children should be supervised, in order to guaran-
tee that they do not play with the heater.
Defects
If the heater does not function correctly, please check
the following points:
• Is the heater charge control set to no-charge?
• Is the complete heating system switched off (via
main switch)?
• Are the circuit breakers in the distribution box loose
or defect?
• If the heater cabinet is warm, but the fan is not
running: Is the room thermostat working? Are the
fuses for the fans in the distributor box loose or de-
fect?
Instructions for the Installer are to be found under
"Trouble Shooting Tips"
Our after-sales service team is of course always
available to help you.