Fault
The refrigerating unit
is switching on more
frequently and for
longer.
The frozen food is
thawing.
Appliance has no
refrigeration capacity.
16
Possible cause
Appliance opened
frequently.
The ventilation
openings have been
covered.
Large quantities
of fresh food are
being frozen.
The ambient
temperature is below
+16° C. The
refrigeration unit is
starting less
frequently.
The temperature
controller is in position
"0".
Power failure.
The fuse has been
switched off.
The mains plug has
not been inserted
properly.
Remedial action
Do not open the appliance
unnecessarily.
Remove obstacles.
Do not exceed max. freezing
capacity.
Increase the ambient temperature
(above +16° C).
Appliances with room temperature
switch Fig. 2/B: To switch on, press
the room temperature switch.
Red mark becomes visible.
The light inside the appliance is lit
at a reduced luminosity.
Turn the temperature controller from
position "0". Fig. 2/A
Check whether the power is on,
check the fuses.