Specifications - Pioneer DRM-1004 Mode D'emploi

Changeur 100 disques
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS

General
System .................................................................. 100 disc changer
Power requirements ..................... AC 100V/120V/230V (switchable)
Current drain .................................................................... 1.6A(100V)
Weight (with disc magazine, without discs) ...... 28.1 kg (61 lb 15 oz)
Dimensions ................................... 263 (W) x 484 (H) x 588 (D) mm
10-11/32 (W) x 19-1/16 (H) x 23-1/8 (D) in
Operating temperature ........................................... +5°C ~ +35°C
Operating humidity .......................... 5% – 85% (no condensation)
Storage temperature .............................................. –40°C ~ +60°C
Functions
Disc storage (12 cm/5-inch discs) ..................................... 100 discs
Removable disc magazines
.................... 2 magazines which hold 50 discs each can be stored.
Accessories
Door key (for front door locking) ................................................... 2
Power cord .................................................................................... 2
Operating Instructions .................................................................... 1
NOTE:
Specifications and design are subject to possible modifications
without notice, due to improvements.
*1
Because the allowed operating temperature and the allowed operating
humidity are limited by the drive that is installed, be sure to use the
drive under the conditions stipulated in the operating instructions for
the drive.
Notes:
For safety, this unit has been designed so that the door cannot
be opened while the built-in reader is operating.
Since the disc rotates at a high speed in the built-in reader,
vibrations or noise may be generated as a result. Note that this
is not a malfunction and that it will not exert adverse effects on
the performance of the unit.
Maintenance
In order to ensure safe and proper functioning of this unit, we
recommend regular maintenance. Extended service life can
be expected if maintained properly.
SCSI connector specifications
50/60 Hz
1.4A(120V)
1.0A(230V)
1) Pin layout of SCSI connectors
*1
+41°F ~ +95°F
*1
Signal name
*1
GROUND
–40°F ~ +140°F
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
NC
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
Notes:
Pin No. 13 is not grounded.
The connectors are of the shielded type.
For details on the control commands, refer to the separate
specifications manual.
2) Electrical specifications of SCSI
Output
characteristics
Input
characteristics
Notes:
Terminate it at both ends of the SCSI bus.
The SCSI interface is single-end type.
Use an SCSI-use high impedance cable (characteristic impedance:
100 ±10 Ω ) with a maximum length of 6 m (total length including
the wiring inside the unit).
1
+
¡
±
Pin No.
1
26
2
27
3
28
4
29
5
30
6
31
7
32
8
33
9
34
10
35
11
36
12
37
13
38
14
39
15
40
16
41
17
42
18
43
19
44
20
45
21
46
22
47
23
48
24
49
25
50
The signals driven by SCSI equipment present
the following output characteristics.
True (LOW):
VOL = 0.0 to 0.5 V DC
IOL = 48 mA (0.5 V DC) max.
False (HIGH): VOH = 2.5 to 5.25 V DC
The signals driven by SCSI equipment present
the following input characteristics.
True (LOW):
VOL = 0.0 to 0.8 V DC
IOL = -0.4 mA to 0.0 mA (0.5 V DC)
False (HIGH): VOH = 2.0 to 5.25 V DC
Published by Pioneer Corporation.
Copyright © 1999 Pioneer Corporation.
All rights reserved.
Signal name
-DB(0)
-DB(1)
-DB(2)
-DB(3)
-DB(4)
-DB(5)
-DB(6)
-DB(7)
-DB(P)
GROUND
GROUND
GROUND
TERMPWR
GROUND
GROUND
-ATN
GROUND
-BSY
-ACK
-RST
-MSG
-SEL
-C/D
-REQ
-I/O
15