Ventilation is deemed sufficient when the room is equipped with air inlets according to the table:
Appliance categories
Fireplaces
stoves
Cookers
INsTallaTION IN PREMIsEs WITH FIRE HazaRDs Is FORbIDDEN. INsTallaTION IN REsIDENTIal PREMIsEs IN WHICH, IN aNY
CasE, THE DEPREssION MEasURED DURINg INsTallaTION bETWEEN THE INTERNal aND EXTERNal ENVIRONMENT Is gREaTER
THaN 4 Pa - REFERENCE FOR ITalY aCCORDINg TO sTaNDaRD UNI10683.
all NaTIONal, REgIONal, PROVINCIal aND MUNICIPal laWs aND sTaNDaRDs IN FORCE IN THE COUNTRY WHERE THE aPPlIaNCE Is
INsTallED MUsT bE COMPlIED WITH.

CANALIZATION OF THE WARM AIR

The heat distribution will take place through the ventilation of the installation environment, or of the adjacent room by the connection in the
back of heat resistant ventilation pipes.
The pipe used for ducting the hot air must have an internal diameter of 100 mm and it must also be insulated or at least be protected against
heat dispersion.
FEaTUREs:
Rear outlet
Diameter of air ducting outlet: 100 mm
Maximum recommended air ducting length 8 mt
Possibility of adjusting the ambient temperature of the ducting via radio thermostat
3 possible settings: OFF, MaNUal, aUTO
DURINg INsTallaTION, IT Is NECEssaRY TO EsTablIsH THE TYPE OF VENTIlaTION OR CONVECTION TO bE aDOPTED
( A OR B sEE CHaPTER INsTallaTION).
Type A - VENTILATION (FaCTORY-sET):
a)
Hot air outlet ONlY from the FRONT of the stove.
b)
Fan oriented as in position A in the INsTallaTION chapter.
Type B - DUCTINg:
a)
Hot air outlet from the REaR of the stove.
b)
Remove the fan with the supporting bracket.
c)
Rotate the fan 180° and secure it in the supporting bracket; the fan air outlet must be aligned with the manifold for the ducting pipe
to be secured (position B INsTallaTION chapter).
40
Reference standard
net opening section with respect to
the appliance fumes outlet section
UNI EN 13229
UNI EN 13240
UNI EN 12815
Percentage of the
50%
50%
50%
ENgLIsH
Minimum net opening value of
the ventilation duct
200 cm²
100 cm²
100 cm²