Les langues disponibles

DIsPLAYs

INDICATIONS
ICONS
-
-
!
-
STEADY
!
-
STEADY
!
!
FLASHING
FLASHING
!
!
FLASHING
STEADY
!
-
FLASHING
!
!
FLASHING
FLASHING
!
!
FLASHING
STEADY
!
!
FLASHING
STEADY
!
!
STEADY
STEADY
DISPLAY
The system is powered but deactivated. Press the dedicated key to activate the
OFF
system.
The system is deactivated. The radio thermostat does not communicate with the
system. Check that the batteries are charged and inserted correctly. Configure
OFF
the radio thermostat (see dedicated paragraph).
If it is not resolved, contact the service centre.
The system is deactivated (OFF). The probe on the combustion chamber is
CAMERA PROBE
disconnected or broken (open circuit). Contact the service centre.
The system is deactivated (OFF) but the temperature on the combustion
chamber is higher than the alarm threshold. Ventilation is activated at the
OFF
intended speed to prevent the product from overheating.
Do not increase the product temperature further.
The system is deactivated (OFF). The probe on the combustion chamber is
CAMERA PROBE
broken or malfunctioning (short circuit). Ventilation is not functioning. Contact
the service centre.
The system is active but the product temperature is below the minimum
activation threshold for ventilation. as soon as the temperature on the
LOU
combustion chamber reaches the ideal value, ventilation will activate as per the
settings.
The system is active. The temperature on the combustion chamber is higher than
the alarm threshold. Ventilation is activated at the intended speed to prevent
HOT
the product from overheating.
Do not load more wood into the product.
The system is active. The radio thermostat does not communicate with the
system and/or the combustion chamber probe is disconnected or broken (open
circuit). set the system to "OFF" and check if and which indications are given.
LOU
Check that the batteries are charged and inserted correctly. Configure the radio
thermostat (see dedicated paragraph).
If it is not resolved, contact the service centre.
The system is active. The radio thermostat does not communicate with the
system and/or the combustion chamber probe is broken or malfunctioning
(short circuit). Ventilation is not functioning. set the system to "OFF" and check
HOT
if and which indications are given. Check that the batteries are charged and
inserted correctly. Configure the radio thermostat (see dedicated paragraph).
If it is not resolved, contact the service centre.
The system is active in aUTO mode. The radio thermostat does not communicate
with the system. Ventilation bases its speed on the last ambient reading taken.
XX °C
Check that the batteries are charged and inserted correctly. Configure the radio
thermostat (see dedicated paragraph).
If it is not resolved, contact the service centre.
ENgLIsH
DESCRIPTION
37

Publicité

Table des Matières