24. Fault Correction

Fault
Water does not flow
Water flows conti-
nuously
Flow duration too
short or too long
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Cause
– Water supply interrupted
– Water-flow volume regulator closed
– Voltage supply interrupted
– Grit filter is clogged
– Solenoid valve faulty
– Sensor faulty
– Solenoid valve faulty
– Flow duration setting incorrect
– Water volume regulator is not fully
opened
– Shower head calcified
– Grit filter is clogged
– Supply pressure too low
- 13 -
Remedy
➯ Restore it
➯ Open it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Clean it
➯ Clean it
➯ Check it

Publicité