displayed alternately with the by-pass setting (display 1 s indicator, 1 s carbonate hardness), at the
bottom left, the meter reading when changing the cartridge (-1) and at the bottom right, the installa-
tion date of the cartridge.
Meaning: the fi lter cartridge most recently used was a PURITY 1200 cartridge, the fi lter cartridge
was inserted on 25/06/05 and operated up to a meter reading of 23166 litres.
The carbonate hardness set was 14°KH and the by-pass measured was 30%.
The same applies to the cartridge(-2), preceding fi lter cartridge and the other preceding fi lter cart-
ridges -3, -4.
Error Messages
The error level E1 indicates whether and from when until when an error has occurred at the water
intake meter.
E1 is activated as soon as the current bypass is not correctly identifi ed.
The word Start is then displayed together with the date of occurrence.
As soon as the current bypass setting is identifi ed correctly again, the error has ended and the Stop
date is added. At error level 01 the Stop and Start display alternates every second.
Error level E2 indicates whether and from when until when an error has occurred at the outlet water
meter. Display is similar to level E1.
Program Overview
20 sec. no activity
Retrieval mode
ID-Information
00 Current level
-1 History level 1
-2 History level 2
-3 History level 3
-4 History level 4
E1 Error inlet metre
E2 Error drainage metre

Operating mode

Carbonate hardness • Ca-
pacity • By-pass • last fi lter
change date
1 x button
alternating
30 sec.no activity =
no Parameter acceptance
Press button 4 seconds
Parameterisation
Filter system type and size
Type of hardness (unit)
and value
Monthly limit
RESET
Parameter acceptance
2 sec.
2 sec.
2 sec.
2 sec.
35