Connecting To Power Supply - Stihl SE 62 Notice D'emploi

Masquer les pouces Voir aussi pour SE 62:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
English
Fastening accessories
Fasten accessories on the holders
provided – as shown in picture.
28

Connecting to Power Supply

The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Extension cord
The design of the extension cord must at
least fulfill the same features as the
connecting cord on the machine.
Observe the design marking (type
designation) on the connecting cord.
The cores in the cord must have the
following minimum cross-section
depending on the mains voltage and
cord length.
Cord length
Minimum cross-
section
220 V – 240 V:
Up to 20 m
1.5 mm
20 m to 50 m
2.5 mm
100 V – 127 V:
Up to 10 m
AWG 14 / 2.0 mm
10 m to 30 m
AWG 12 / 3.5 mm
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off –
see "Switching off the machine"
Plug the power cord or extension
N
cord into a properly installed outlet
2
2
2
2
SE 62, SE 62 E

Publicité

Table des Matières
loading

Table des Matières