TCX07, TCX14, TCX21, TCX35
➤ Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
8

Disposal

➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
9

Troubleshooting

Fault
The cooling device
does not function and
the fan impeller which
is visible from outside
does not rotate.
The ignition is switched
on and the cooling
device does not work.
EN
Possible cause
There is no voltage
present in the DC
power socket in your
vehicle.
The DC power socket
is dirty. This results in a
poor electrical
contact.
The fuse of the
connecting cable is
burnt through.
The vehicle fuse is
burnt through.
Suggestion
The ignition must be switched on in most
vehicles to apply current to the DC power
socket.
Clean the socket of the DC power socket
with a non-metallic brush and a solvent,
so that the middle contact pin is clean.
If the plug of your cooling device
becomes very warm in the DC power
socket, either the DC power socket must
be cleaned or the plug has not been
assembled correctly.
Replace the fuse (fig. 7 1, page 5) of the
DC plug with one of the same rating.
Replace the vehicle fuse of the DC power
socket (usually 15 A). (Observe the
operating instructions in your motorcar
for this).