SAFETY CRITERIA
1
Attention: before beginning anykind of procedure of installation is absolutely
necessary to read all this manuall.
2
Test/Control that the perfornces of the actuator auswer to your installation needs.
3
Besides control that:
• The gare hinges are in good conditions and perfectly fattened.
• The gate has mechanicall stops in the opening and the closing.
INSTALLATION ADVICE
Connections:
•
See the "Scheme Functional " and refer to the control central scheme.
•
The electric cable in the exit from the actuator must be tight, but do an ample curve
towards the botton in order to avoid the reflux in the inside of the actuator itself.
(Fig. 12)
•
The adjustment must be effected when the device has no power supply.
•
Foresee a omnipolar breaking device near to the apparatus (the contact must
measure at least 3 mm) Always protect the power supply using a 6A automatic
switch, or a 16A single-phase switch fises.
•
The power supply lines the motors, to the control unit and the connection lines to
the outfits must be sepated to avoid troubles which could generate problems in the
installation working.
•
Any outfits (of control or safety) eventually connected to the control unit must be
tension free.
Spare parts:
•
use esclusively original spare parts.
Installation:
•
In order to correctly use the product and to exclude the possibility of injury or
damage, refer to the "Generals" page enclosure, which is an integrated part of this
manual.
•
The use of this equipment must be in observance of the safety standards in force in
the country where it is installed, as well as the standards governing proper
installation.
Warranty:
•
The warranty supplied by the manufacturer becomes void in the event of
interference, carelessness, improper use, lightening damage, power surges or use
by unqualified personnel.
•
The warranty will also become void in the event of the following: Failure to observe
the instructions given in the manuals supplied with the product.
The application of any part in a manner differing from that provided for current
legislation or the use of spare parts which are unsuitable and/or not approved by
manifacturer.
•
The manufacturer cannot be held responsible for damages due to improper or
unreasonable use.
INSTALLATION INSTRUCTION SEQUENCE
1
Before the installation, anomalyse the risks referring to the chapter "Generalities"
of this instructions manual, fill the technic table and eliminate the risks a noticed. In
case of more risks, foresee th installation with security system.
2
est the security laws of the "Security Criteria".
3
Identify the rigut actuator and left actuator.
4
Control all the components.
5
Identify the fixing point on the gate and then on the pillar.
6
Verufy ponit "D"
7
Adapt the clampt BR_A o BR_B following "Table1"
8
Anchor the piston to the clamp BR_A o BR_B.
9
Unclamp the actuator
10 Anchor the clamp BR_C on the gate
11 Anchor the manina of the piston to the clamp BR_C.
12 Strech the wires as in the "Functional Swing "
13 Connect the central and all the accessoires
14 Program the radio receptor
15 Pèrogram working times
In case of badworking, see the "Anomalies and Counsuls"
If you do not find any slution coll the neatest Assistence centre.
LOCKED ACTUATOR
The actuators may be either locked.
Please notice that the electric lock must be installed on the wing that opens first and
must be connected with the terminal board of the control unit.
Position of the electric lock: (Fig. 4).
Position 1: Lock between the wings
Position 2: Lock in the floor (in this case the utilisation of the bolt is not essential).
Remenber to remove the lock or at least block the lock in opening position and take away
all the bolts of lock.
RIGHT OR LEFT ACTUATORS (Fig. 5)
The actuators are supplied in Right or Left version.
Right or left are established looking the gate from the side where the actuators are
installed, if the hinges are on the right the actuator is right, if they are on the left the
actuator is left.
DETERMINATION OF FIXING MEASURES
GATE FIXED IN THE MIDDLE OF THE PILLAR (Fig. 2)
In this case the maximal opening corner of the gate is 90°.
-
The correct functioning can be obtained putting the fixing brackets at the measures.
In the case that will be difficult to realise do as follows:
-
Measure the level D (distance between the hinges' axis and the pillar's edge)
-
Look the table 1 up and follow the correspondent line of the model of your operator
untill you cross the line correspondent level D.
-
In the finded table you can see the necessary indications and establish the most
suitable use of the bracket BR_A or alternatively braket BR_B (Fig. 7).
These quotes are calculated in order to obtain an average tangential speed that does not
exceed of 12 m/minute.
GATE FIXED ON THE EDGE PILLAR (Fig. 3)
In this case the gate can open with a corner superior to 90° (max. 120°)
-
The correct functioning for a 90° deegrees opening is obtained putting the backets
to the measures indicated in the table above picture A and B.
-
To obtain that the wing will open with a bigger corner is necessary that measure A
will be superior to measure B.
The best solution can be obtained increasing measure A of the same dimension of wich
must be diminished the measure B.
HEIGHT INSTALLATION
Calculate the height of the actuator installation according to the gate's shape and the
fastening possibility. (Fig. 6)
a) If the gate has a big structure you can position it at any highness with no limits.
b) If the structure is light is necessary to put the operator as muca as near as possible
to the centre of the gate (in heigt).
Position 1 Central beam of the gate
Position 2 Stiffen of the gate
Keep attention from the base of the actuator collar and the floor have to remain more
than 10 ÷15cm.
Bolt or weld the bracket BR_A or BR_B on the gate's side pillar, keeping in mind that
the measures A and B refer to the gate hinges axis and to the actuator's rotation axis.
In case of fastening by expansion bolts, use Ø 13 mm metal bolts and place the bolt at no
less than 30÷35mm from the pillar's corner, to avoid any corner breaking.
In case of masonry pillars, use chemical or resin bolts or a perfectly stoned bracket.
-
Be careful to the utilisation of the bracket BR_A (Fig. 7) which disposes of two
versions bracket BR_A right end bracket BR_A left, that should be used with its
actuator; left or right.
-
Fasten the actuator to bracket BR_A as indicated in "Fig. 8" remenbering that the
threaded hole of the rotating pivot PR_A must be turned down.
BRACKETS S2 (Fig. 7)
In some ways as indicated in table 1 and for particular installation is suitable to use
bracket BR_B. Each bracket is composed of 1 a squared plate with dimensions 130x130x6
mm, wiyh 4 holes of Ø12 mm and n°1 112x94x55 mm with 3 holes of Ø 12 mm.
Instructions for sutting up
-
Screw the plate to the pillar wuth strong dowels
-
To weld the bracket to the plate as indicated in Fig. 7
Remember that the measures A and B are refferred to the hinges axis of the gate and
the rotation axis.
FRONT BRACKET'S FIXING
Determine the position of bracket BR_C as follows:
-
Close the gate's wing.
-
Rotate counterclockwise the actuator's manina until the end-of-stroke position of
the rod (the rod is completely out), then rotate the manina clockwise until the
manina fixing screw is down-sided.
In any case the manina must be rotated of half a turn at least.
-
Fasten bracket BR_C to the manina of the actuator as indicated in "Fig. 9"
remenbering that the threaded hole of the rotation pivot PR_A must be turned down.
-
Position the actuator on the gate's wing keeping it levelled and mark the position of
bracket BR_C on the gate.
-
Weld or bolt bracket BR_C to the gate.
MECHANICAL STOP (Fig. 5)
At this point you need to position the mechanical stop to proceed, respectively, to the
wing's closing and opening stop.
EXTERNAL OPENING GATE
In case of external opening gate is possible to place the actuator towards the internal
side.
In this case the quote A (distance between the axe of the hinges and the rotation axe of
the actuator) has to be mesured towards the center of the gate (Fig. 10).
And is necessary to modify the bracket S2 to adapt it to the new fixing position.
In order not to reduce the lenght of the passage the actuator can be positioned in the
superior part of the gate at a hightness uninferior of 2 mt.
The position of the front bracket will be founded with the method indicated upon, but
with the open wing of the gate.
Due to the motor's power, all the fastenings must be strong.
RELEASE OF THE ACTUATOR
-
Insert the key (supplied in the kit) and rotate it of 90° many times towards the
center of the gate (Fig. 11).
-
At this point the gate may be opened or closed manually.
-
Do the inverse operation to clasp the actuator.
To link the actuator up turn in opposite direction the provided key.
It is not necessary that the gate is not in a specific position because to a next start will be
restored all the previous value
BRAKET FIXING