• Move the flow control lever (2) as far as it will go to
the "OFF" position. Push the feed plate back as far as it
will go to the closed position. See figure 10.
• Place a nylon washer (36) onto the bent end of the
flow control link (44) and then insert the link into the feed
plate bracket. Secure it with a 3/32" x 3/4" cotter pin (24).
See figure 10.
• Tighten the lower 1/4" nylock hex nut (26) until it
touches the bottom of the ferrule, then tighten the upper
1/4" nylock hex nut (26) until it is snug against the top of
the ferrule. See figure 10.
• Hook the open end of the spring (40) into the feed
plate. Place the closed end of the spring onto the end of
the hex bolt in the flow control lever. Secure it with a 1/4"
nylock hex nut (26). See figure 10.
• Open and close the feed plate using the flow
control lever. Check to make sure the feed plate is
closed completely when the lever is in the "OFF"
position. If the feed plate does not close completely,
adjust the 1/4" nylock hex nuts (26) on the flow con-
trol link (44). See figure 10.
26
26
44
FEED PLATE
FIGURE 10
2
26
40
24
36
• Push two flanged bearings (22) into each of the drive
disks (8). See figure 11.
8
22
FIGURE 11
• Push a flanged bearing (22) into each of the seven
spike disks (7), from the side shown in figure 12.
7
FIGURE 12
• Press flanged bearings (22) into both of the end plates.
See figure 13.
• Place the 1/4" thick spacer (50) onto the spike disk
shaft (12) and then insert the shaft through the flanged
bearing (22) in the left hand end plate. See figure 13.
22
FIGURE 13
9
22
22
22
50
12