Clarke FOGUS C28 Manuel De L'utilisateur page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
Adjusting Squeegee Blades
When properly installed the front blade should be ap-
proximately .12 above the rear blade. See figure #29.
WARNING: Maintenance and repairs
must be
ized personnel only .
WARNING: Electrical repairs must be
done by authorized per-
sonnel only.
Consult your Clarke Authorized Service Person to
do the service procedures.
Use only genuine Clarke parts.
How to Clean the Solution Line
If the solution line becomes clogged, pull the filter
assembly out from behind the brush housing (figure
30). Turn solution vavle off. Remove the filter screen
(figure 31, B) and clean or replace it. Turn solution
valve back on (figure 31, A) and push filter assembly
back inside frame.
®
Clarke
Operator's Manual (EN) - FOCUS C28 and C33
done by author-
ENGLISH
0.12" (3.0 mm)
Figure #29
Figure #30
A
Figure #31
EN
B
- 21 -