CONNECTIONS

TAMPER

CONFIGURATIONS

The siren is configured by means of wire jumpers, apart from the ringing level and the power set-up that is set
using the jumpers (JP2 and JP6). The jumpers functions are listed (factory programming in block letters):
IDENTIFICATION
JP1
JP2
JP3-JP4
JP5
IDENTIFICATION
JP6
(1)
For HP305P version the battery is mandatory.
JP1 JP2 JP3 JP4
JP5
TAMPER TC1
BL1
+
Connecting anti-tamper micro-switch
TC1
TC input
BL1
BL1 input
+
To power supply positive
-
To power supply negative
BL2 input
BL2
FUNCTION
Input BL2
BL2 Sound Level
Timeout ringing lock
BL1, BL2 and TC
inputs references
FUNCTION
Siren power-up
3
2
JP6
1
+
_
_
BL2
TO THE BATTERY
CLOSED
BL2 not used
High level
JP3 closed – JP4 closed = 30 min
JP3 open – JP4 closed = 9 min
JP3 closed– JP4 open = 6 min
JP3 open – JP4 open = 3 min
To positive
(1)
POSITION 1-2
With battery
(Self powered siren)
14/16
OPEN
BL2 active
Low level
To negative
POSITION 2-3
Only from Control Panel