Important!
After having carried out the conversion to another type of gas, it is necessary to update the data plate, indicating the
type of gas for which the appliance has been converted.
•
The instructions necessary for use are enclosed with the appliance.
•
Check the appliances for gas leaks.
•
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
•
Check the lighting and flame of the main burner.
•
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is essential to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must only be done by specialised personnel, observing the norms in force and our indications.
It is possible to substitute parts such as the valve, the piezoelectric lighter or gas pipes very simply. To substitute the
parts, proceed as follows:
•
Valve: after removing the front panel, unscrew the screwed fittings of the gas connections, then substitute the
faulty parts, installing the new ones in sequence.
•
To substitute the thermocouple, unscrew the pilot burner fitting, likewise the valve fitting and substitute the
element.
•
The spark plug must be unscrewed and substituted.
Attention!
Before lighting the appliance, it must be washed with water and washing-up liquid, rinsed thoroughly and filled with
water up to the level indicated by the mark on the back of the water tub.
DO NOT START UP THE APPLIANCE WITH THE WATER TUB EMPTY.
The system must be connected to a drinking water supply with the following characteristics. Failure to do so
automatically invalidates the guarantee
Total hardness: 0,5 to 5°F to prevent the build-up of lime-scale
Pressure: 50 to 250 kPa (0,5-2,5 bar).
Chlorine ion concentration (Cl-): not more than 10 ppm (acceptable value) to avoid damaging the internal steel
elements
pH: over 7
Electrical conductivity: 50 to 2000 µS/cm (20°C)
It is advisable to connect the appliance to the hot water pipe (max.60°C) to reduce heating time; it is also recommended
to install a cut-off cock upstream from the appliance.
The drain piping must be connected to a suitable drain and be compliant with the norms.
The piping must be connected in such a way as to avoid contractions or siphons. Drainage of the water is free, therefore
it is essential that the drain is lower than the outlet of the piping.
Before using the appliance, it is necessary to clean it carefully, especially the water tub (see paragraph "cleaning and
care").
Check the connection of the appliance and start it up following the instructions, "Instructions for use".
Attention!
- Use the appliance only under surveillance.
Water filling
Check that the drainage tap is in the "off" position.
Fill the tub with water up to the level indicated by the mark, by pressing the button.
GB
CHECKING FUNCTIONING
MAINTENANCE
SPARE PARTS
WATER SUPPLY CHARACTERISTICS
WATER CONNECTION AND DRAINAGE
STARTING UP
43
IE