ANOMALIES MOD. CP...

If the probe does not detect the presence of water in the tank for more than 15 sec. the system disables the heating
element: the alarm is indicated by a flashing red light
When the probe returns to detect the presence of water, the heating element is activated and the red light is turned off
NOTE: the filling phase is monitored by the system through the TIME-OUT.

PASTA COOKER WITH AUTOMATIC LOADING

If the probe does not detect the presence of water, the system will restore the correct level and after 15 sec. it will
disable the heating element: the alarm is indicated by a flashing red light
When the probe returns to detect the presence of water, the heating element is activated immediately and after 3 sec. the
automatic refilling is stopped
NOTE: the filling phase is monitored by the system through the TIME-OUT.

Slow refilling button

When the "slow refilling button" is active the system will fill the tank slowly so as to eliminate any foaming.

Level button

The "level button" defines the level of the water in the tank: high level for cooking the pasta, low level for steaming.
Important: keep clean the probe level

TIME- OUT

After discovering the level probe, the micro controller triggers an internal timer relative to the duration of this phase. If
(continuous) loading takes longer than 350 seconds, the system blocks the functions of the device and the alarm is
signaled by the steady red light.
To reset the alarm condition, after removing the fault that caused the intervention (broken or disconnected level probes,
problems with the water supply, drain valve open...), the system must be turned OFF/ON.

TURNING OFF THE APPLIANCE

Push and turn the knob into position "0". This command blocks the gas supply to both the main burner and the pilot
burner. To relight the appliance, it is necessary to turn the knob again into position * and press the button.

EMPTYING THE TUB

To carry out this operation, it is necessary to open the outlet tap (lever in vertical position) which can only be reached
through the cabinet door situated below the appliance.
NB:
it is recommended to carry out this operation using water which is not too hot.