CODE
ERROR/WARNING
E111
Fume probe malfunction
A001
Low pellet level. (flashing icon)
Scheduled maintenance warning. (flashing
A002
icon)
A004
Low battery
Pressure sensor malfunction.
A007
(flashing icon)
----
Stove cleaning
----
Ignition failure error
After checking the message type, it is possible to reset the alarm by pressing the on/off key
seconds.
If the error code is "E108", manually re-set the thermostat on the back of the stove before resetting the
alarm (Fig. 6.1) (to be performed by the technical support centre).
Before switching on again, check that:
•
the stove has cooled down;
•
the burn pot is clean and free from ash residue or pellets;
•
the burn pot is correctly positioned in its seat;
•
the fire box and tank doors are firmly closed.
Before switching on again, check that:
•
the stove has cooled down
•
the burn pot is clean and free from ash residue or pellets
•
the burn pot is correctly positioned in its seat
•
the fire box and tank doors are firmly closed.
* If the event of a black-out, the stove must be reconfigured when the electricity comes back on (see par.
"3.3 Initial settings" in this manual).
004778040 - 07/10/2020
ITALIANO
ENGLISH
DESCRIPTION
DEUTSCH
FRANÇAIS
POSSIBLE CAUSES
Defective fume temperature probe
Pellets depleted
Periodically, the stove requires maintenance by a
specialist technician
The back-up battery (mod. CR2032) on the electronic
board is low *
Pressure sensor or faults card.
Combustion chamber, burn pot or dirty fume
evacuation.
Detached or blocked pressure detection tubes.
Blocked combustion air intake.
No pellets: Ignition resistor faulty;
Worn gaskets; Incorrect burn pot position
ESPAÑOL
LED
for a few
Fig. 6.1
31