Table 5.
General Specification
ENG
Umgebungsbedingungen
GER
Caractéristiques Générale
FRE
Descrizione Generale
ITL
Especificación de carácter general
ESP
Description
Operating Temperature
Humidity
Device and RTC Backup
RTC Accuracy
Noise Immunity
Dialectric Withstand Voltage
Insulation Resistance
Vibration Resistance - Direct
Mounting
Vibration Resistance - DIN Rail
Mounting
Shock Resistance
Protection
Certifications
Complies With
Table 6.
Circuit Protection (Fuse)
ENG
Schaltkreis-Schutz (Sicherung)
GER
Protection du circuit (fusible)
FRE
Dispositivo di protezione circuito (fusibile)
ITL
Voltaje de la protección del circuito (fusible)
ESP
Circuit Voltage
5 Volt
12 Volt
24 Volt
100V AC
240V AC
** <= 1/2 Power Source
Example Fuse Size Calculation
12V
2A

2. WIRING DIAGRAMS

Figure 1. Recommended Power Wiring Diagram
!
"
+
L
MC
N
L
N
'
+
0-55°C
35 - 85% Relative Humidity, no condensation
20 days at 25 °C
5 seconds/day at 25 °C
1000 Vpp, 1 microsecond, 30 - 100 Hz, tested by noise simulator
3750V AC > 1 min per EN60730-1 between the following points:
All Terminals and the DIN 43880 Control box or equivalent
7 Mohm at 500V DC per EN60730-1 between the following points:
All Terminals and the DIN 43880 Control box or equivalent
Conforms to IEC 68-2-6; 10-57 Hz: 0.15 mm Constant Amplitude
57-150 Hz: 19.6 m/s
Sweep Count for X,Y,Z: 10 times (80 minutes in each direction)
Conforms to IEC 68-2-6; 10-57 Hz: 0.075 mm Constant Amplitude
57-150 Hz: 9.8 m/s
Sweep Count for X,Y,Z: 10 times (80 minutes in each direction)
Conforms to IEC 68-2-27: 147m/s
3 times in each direction X,Y, and Z
IP20
CE, UL/cUL
UL 508, EN60730-1, EN61010-1, EN50081-1, EN50082-1,
EN61000-6-2
Relay
Circuit Protection (Fuse)
-----
-----
-----
10 Amps per Circuit
10 Amps per Circuit
Fuse Size:
1A <= (1/2 X 2A)
#
MC
%
&
Start
$
(
MC
MC
"L" and "N" terminals are not
reversible.
Specification
Storage Temperature
Power/Input Terminals and Relay Output Terminals
Relay Output Terminal and Relay Output Terminal
Power/Input Terminals and Relay Output Terminals
Relay Output Terminal and Relay Output Terminal
2
Acceleration
2
Acceleration
Grounding
Attestation of Conformity
Circuit Protection (Fuse)
< 0.3 Amps per Circuit
< 2.0 Amps per Circuit**
< 2.0 Amps per Circuit**
Ref.
1
AC Power Supply
2
Circuit Isolation Device
3
Emergency Stop
4
Power On Pilot Indicator
5
Circuit Protection Device - Limit to 1.0 Amps.
6
Power Supply for AC Loads
7
Magnetic Switch Contact
α
8
Base Unit
(-30) - 70°C
2
Acceleration, Action Time: 11 ms
Not Required
TÜV
Transistor
-----
-----
Item Description