Figure 7 – Powering the Unit with AC Adapter
Installing the Imager Head
Cable or Extension Cables
To use the micro CA-300 Inspection Cam er a,
the imager head cable must be connected
to the handheld display unit. To connect the
cable to the handheld display unit, make sure
the camera socket key and display unit socket
slot (Figure 8) are properly aligned. Once
they are aligned, finger tighten the knurled
knob to hold the connection in place.
Figure 8 – Cable Connections
3' (90 cm) and 6' (180 cm) cable extensions are
available to increase the length of your camera
cable up to 30 feet (9 m). To install an exten-
sion, first remove the camera head cable from
the display unit by loosening the knurled knob.
Connect the extension to the handheld as de-
scribed above (Figure 8) . Connect the keyed
end of the camera head cable to the slotted
end of the extension and finger tighten the
knurled knob to hold the connection in place.
Installing Accessories
The three included accessories, (Hook, Mag -
net, Mirror) all attach to the imager head the
same way.
Figure 9 – Installing an Accessory
To connect, hold the imager head as shown in
Figure 9 . Slip the semicircle end of the ac-
cessory over the flats of the imager head.
Then rotate the accessory a 1/4 turn to retain.
Installing SD™ Card
Open the left side port cover (Figure 4) to ac-
cess the SD card slot. Insert the SD card into
the slot making sure the contacts are facing to-
wards you and the angled portion of the card is
facing down (Figure 10) . SD cards can only be
installed one way – do not force. When an
SD card is installed, a small SD card icon will
appear in the upper left hand portion of the
screen, along with the number of images or
length of video that can be stored on the SD
card.
Figure 10 – Inserting the SD Card
Pre-Operation
Inspection
Before each use, inspect your Inspec -
tion Camera and correct any problems
to reduce the risk of serious injury from
electric shock and other causes and
prevent tool damage.
Accessory
1. Make sure the unit is OFF.
2. Remove the battery and inspect it for
micro CA-300 Inspection Camera
WARNING
signs of dam age. Re place battery if nec-
essary. Do not use Inspection Camera if
the battery is damaged.
7