Installation Instructions; Dip Switches - Danby DPTA090HEB1WDB Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

DIP SWITCHES

Dip switch controls are located behind the front
panel through an opening below the control panel.
Remove the front panel to access the dip switches.
Dip switches are accessible without opening the
control box.
The appliance should be unplugged before making
adjustments to the dip switches.
DIP SWITCH CONFIGURATIONS
See the table below for dip switch confi gurations and functions.
1 2 3 4
Number UP (ON)
S1
Electric heat only
S2
Temperature display °F
S3
Wall thermostat enable
S4*S5
UP*UP: 61°F ~ 86°F (16°C ~ 30°C)
UP*DOWN: 65°F ~ 78°F (18°C ~ 26°C)
DOWN*UP: 63°F ~ 80°F (17°C ~ 27°C)
DOWN*DOWN: 68°F ~ 75°F (20°C ~ 24°C)
S6
Fan continuous run for heating
S7
Fan continuous run for cooling
S8
Low temperature protection enable Low temperature protection disable
S9 (S3
Use some types of wall thermostat
UP)
S9 (S3
Use control panel only
DOWN)
Sw11
Load delay for 3 seconds
1 2 3 4
1 2
A0-
A3
DOWN (OFF)
Electric and pump heat
Temperature display °C
Control panel enable
Fan cycle for heating
Fan cycle for cooling
Use PTAC other wall thermostat
Use control panel or some types of
wall thermostat
Normal
UP(ON)
1 2 3 4
DOWN(OFF)
Wall thermostat
Load delay for 3 seconds
Heating type
Temperature display type
Control type
Setpoint limit 1
Setpoint limit 2
Fan CON/CYC for heating
Fan CON/CYC for cooling
Low temp. Protection
4
type
Remarks
Heat pump model
only
Confi guration of S4
and S5 combine to
select set point range
Consult with
sales agent or
manufacturer for
details
Optional

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dpta120heb1wdbDpta150heb1wdb

Table des Matières