Irrigation Modes

Programmed Irrigation:
WR2 Wireless
Sensor is actively
managing
the irrigation
controller / timer. Once a set point is satisfied
by environmental conditions, or the "Quick
Shut Off " feature is activated, irrigation is
suspended. An X and corresponding trip
indicator (rainfall, temperature, or both)
will automatically display when irrigation is
suspended.
Suspend Irrigation for 72 Hours:
User has elected to
temporarily suspend
irrigation for 72
hours. System will
automatically resume
programmed irrigation
mode after 72 hours (Note: X and trip
indicator will be displayed when returning to
programmed irrigation mode if set points are
satisfied).
Override Sensor for 72 Hours:
User has elected
to permit
irrigation in
accordance
with the timer schedule regardless of
environmental conditions (i.e. rainfall
or low temperature is detected by the
sensor). System will automatically resume
programmed irrigation mode after 72 hours
(Note: X and trip indicator will be displayed
when returning to programmed irrigation
mode if set points are satisfied).
WR2 user manual (637469-01) EN ESMX FRCA.indd 5
WR2 Wireless Sensor • www.rainbird.com/WR2
Synchronize
the Sensor and
Controller Interface
After the Controller Interface is wired
to the irrigation timer, the Sensor and
Controller Interface need to establish a
radio communication link. When the link
is established, the Sensor and Controller
Interface are considered "paired."
1. On the Controller
Interface, push and
hold both arrow
buttons simultaneously
to begin the installation
sequence.
2. After the "Sensor Indicator / Pairing Status"
icon flashes, remove the label from the
bottom of the sensor.
3. The flashing "Sensor Indicator / Pairing
Status" icon prompts you to insert the
battery cassette with battery into the Sensor
lower casing as shown. Align the arrow
on the battery cassette with the unlocked
indicator on the bottom of the Sensor.
Lower
Casing
4. Rotate the battery cassette clockwise
until the arrow points toward the locked
indicator. The light on the bottom of the
Sensor will blink once to indicate that the
sensor is now powered up.
Locked
Position
LED flashes
when
cassette is
locked
Unlocked
Position
Battery Cassete
and CR2032 battery
5