Télécharger Imprimer la page

Technical Data - SFA SANIBEST Notice D'installation

Broyeur

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
UK
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
1
DESCRIPTION
This pump/macerator has been designed to pump away the
waste from a WC and the sanitary appliances mentioned in fig
. SANIBEST
is a robust machine which is capable of
®
1
handling occasional sanitary article accidentally flushed down
the WC. Installed and used correctly, SANIBEST
consistent and reliable service.
Please note the following warning signs:
"
" Possible danger to personnel,
"
" Warning of possible electrical hazard,
"
" Instructions for use only by qualified professionals,
"WARNING" This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
2
LIST OF ACCESSORIES INCLUDED
3
DIMENSIONS
4

TECHNICAL DATA

Application
Type
Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption 3,5 A
Electric Class
Degree of protection
Net Weight
Only installations conforming to the above
WARNING:
specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL PUMPING
COMBINATIONS
7
INSTALLATION
The unit must be connected to a WC pan with
WARNING:
horizontal outlet spigot conforming to EN33 or EN 37 norms.
The Sanibest should be installed so that it is accessible for
possible maintenance
The macerator has fastenings preventing it turning or from
floating.
7a
CONNECTION TO A WC
1
- Pull flexible sleeve over the pan spigot
2
- Position the metal hose clip
flexible sleeve, and tighten with a screwdriver
will give
®
1 WC + + shower
+ bidet + washbasin
LA05-B81
max. 6 m
220-240 V
50 Hz
760 W
I
IP44
9,5 kg
over the edge of the
A
7b
CONNECTION OF THE DISCHARGE PIPEWORK
1
- Use the elbow and the stepped sleeve
2
- Insert the sleeve on the elbow. Fix it in place with a
collar
.
D
3
- Orient the assembly as required and push it well into
the black rubber pipe 7 . Fix the base of the elbow in
place with a collar
D
4
- Cut off the end of the sleeve, if necessary, to suit the
diameter of the discharge pipe and use a collar
.
J
5
- We advise installing a drain valve at the low point to
facilitate maintenance.
6
- To avoid siphoning, fit an anti-syphon valve (capable of
withstanding about 10 psi pressure) at the high point, or
increase the diameter of the horizontal pipe.
• All horizontal piperuns require a 1:100 fall.
• If a vertical lift is required, this must be installed at the
start of piperun and a 1:100 fall given to the pipe from
the high point to the drain.
• All bends should be smooth/slow (eg pulled bens or
2 x 45 degree bends together). Do not use 90° elbows.
• If the horizontal piperun exceeds about 10 metres, increase
the size from 22 mm to 32 mm from that point onwards.
7c
CONNECTION OF THE OTHER SANITARY
APPLIANCES
1
- To connect to the side entries of the case, use the
rubber connector
. Secure with clips
C
2
- Plug the unused inlet with blanking plug
greasing the joint.
Ensure when connecting a shower to
WARNING:
that the underside of the shower tray is
®
SANIBEST
raised by at least 15cm from the floor.
7d
CONNECTION OF A WASHBASIN
The washbasin can be connected in two ways.
To one of the side inlets (see
Or to the raised inlet that can be cut open on the cover.
To do so:
• Cut off the top of the raised inlet with a saw.
• Do not leave any sharp angles on the edge of the cut.
Remove any burrs.
• Insert a sleeve
in the hole in the cover.
C
• Insert the Ø 32 mm waste pipe from the washbasin
into the sleeve (clips
7e
VENTING
is fitted with an active carbon filter, and requires
SANIBEST
®
no external venting.
7f
EXAMPLE OF SANIBEST
7g
ELECTRICAL CONNECTION
The electrical installation should be carried by a
qualified person and conform to BS 7671 1992
requirements for electrical installation.
The unit requires a 220/240V single phase AC 50 Hz supply
(UK specification). Do not connect the unit to a conventional
plug and socket.
The unit should be connected to a fully earthed electrical
supply (class 1). It must be wired into an unswitched fused
fixed wiring connector protected by a 5 amp fuse and a
residual current detector (30 mA). This connection must be
used exclusively for supplying the unit.
The unit should be sited at least 60 cm away from any
shower tray.
.
B
.
and
D
after
F
7c
)
supplied).
D
®
' INSTALLATION
or
E
.
E

Publicité

loading