DESCRIPTION
This grinder/pump is manufactured in a factory which is quali-
ty certified to ISO 9001 (2000) accredited by AFAQ. To benefit
from the advantages provided by this new generation system,
it is important to comply with the installation instructions.
The grinder/pump unit is a residential and commercial pum-
ping system for toilet and bathroom fixtures. As shown in fig
n ° 1, it can simultaneously receive wastewater from sanitary
fixtures such as a sink, shower, bathtub but only one toilet
per unit. It is also powerful enough to handle wastewater from
a washing machine through an indirect connection (via utility
sink).
The SANIBEST Pro
®
is designed for the disposal of human
waste, toilet paper and water. It is also capable of handling
occasional sanitary articles flushed down the toilet. They are
not intended to be used for the disposal of kitchen waste
or directly from pump appliances such as a dishwasher.
Installed and used correctly, the SANIBEST Pro
consistent and reliable service.
Please note the following warning signs:
«
» Possible danger to personnel,
«
» Warning of possible electrical hazard,
«
» Instructions for use only by qualified professionals,
«WARNING» This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
2
LIST OF ACCESSORIES
3
DIMENSIONS
4
TECHNICAL DATA
Application
Vertical Pumping
Voltage
Frequency
Amperage
Motor
Temperature
Degree of protection
Net Weight
WARNING:
Only installations conforming to the above
specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL PUMPING
COMBINATIONS
7
INSTALLATION
The grinding system must discharge into a minimum 3/4-inch
sanitary drainage pipe. The system will pump up to a maxi-
mum of 25 Ft vertically and then across with a 1/4" per foot
gravity fall (minimum) constantly throughout the horizontal run
to the point of discharge. If you require a vertical lift, it should
®
will give
1 toilet + shower/bathtub,
sink
Max. 25 Ft
110-120 V
60 Hz
Max. 9 Amps
1 HP
Max. 104° F
IP44
26 lbs
precede any horizontal run and should commence as near
as possible to the discharge elbow (no more than 18 inches
away). Once you have started the horizontal run, you cannot
change directions in an upward vertical manner.
The unit has fastenings on the bottom of the casing. This is
meant to secure the pump to the floor and prevent it from
turning.
TANK AND WATER SUPPLY CONNECTION
The tank comes with the fill and flush valve already
assembled. The hardware kit to assembled the tank to
the bowl comes included with the system. Ensure that all
screws, nuts, etc are tightened and well secured. Connect
the water supply hose to the bottom connection of the fill
valve.
7a
CONNECTION TO THE TOILET
1 - Stretch the flexible sleeve over the entry connection of
the casing
2 - Secure this connection with the cable tie supplied
3 - Push the metal clamp around the flexible sleeve and
then pull the sleeve over the exit spigot of the bowl
4 - Position the metal clamp at the edge of the flexible
sleeve and secure this by tighten the metal clamp with a
screwdriver
7b
CONNECTION OF THE DISCHARGE PIPE
These systems are provided with a discharge elbow which
has a built-in check valve, a flexible discharge hose, a plastic
coupling and a step-down rubber connection. Follow these
steps to connect to your discharge pipe.
1 - Insert the larger end of the plastic discharge elbow into
the rubber discharge hose coming out from the top of
the pump.
2 - Rotate the discharge to any direction and secure the
base of the elbow with a clamp.
3 - Connect the flexible hose to the smaller end of the dis-
charge elbow and secure with a clamp.
For 3/4" CPVC (22 mm)
4 - Insert the discharge pipe inside the flexible hose and
secure with a clamp.
For 3/4" PVC (28 mm)
4 - Insert the smaller end of the plastic coupling inside the
flexible hose ; secure with clamp.
5 - Connect the step-down rubber connection to the other
end of the plastic coupling; secure with a clamp.
6 - Insert the discharge pipe inside the step-down rubber
connection and secure with clamp.
For 1" PVC (32 mm)
4 - Insert the smaller end of the plastic coupling inside the
flexible hose; secure with clamp.
5 - Connect the step-down rubber connection to the other
end of the plastic coupling; secure with a clamp.
6 - Cut off the end of the step-down rubber connection to fit
the 1" pipe; secure with clamp.
NOTE:
Use only 3/4" or 1" pipe for the discharge.
Install a ball valve in the discharge line in order to facilitate the
removal of the unit.
If you want for the unit to pump vertically and horizontally,
you may calculate that 3 Ft of vertical lift is equivalent to 30
Ft of horizontal run. Note that all horizontal runs require a 1/4"
per foot gravity fall.
Each bend or change in direction causes minor losses which
must be deducted from the discharge performance (ie.
reduce discharge height by 3 Ft for each 90 degree turn). Use
long sweeping 90 degree elbows or two 45 degree elbows
back-to-back to create the 90 degree turn. Do not use 90
degree elbows.
The connection to the soil stack or sewer pipe should be