5.
OPERATION:_________________________________________________________________________________________________
5.1.
System on stand-by
The system goes into "STAND-BY" when the "" [3] key is pressed until the "0%" light blinks. When this occurs, there is no production in the
electrolysis cell.
5.2.
Production level selection
To select the desired production level, press the "" [3] / "" [2 keys until the production level light blinks. The system will set its production
to the desired level after a few seconds.
The production setpoint could be visualized at any time by pressing once the "" [3] key or the "" [2] key.
WINTER Mode: during periods of low water temperature, where the chlorine demand will be low, select a production level [1] of 60%,
because in this way power consumption and lifetime of the package of electrodes are optimized.
5.3.
TEST Mode
To enter TEST MODE, reduce the production level to "0%" by pressing the key "" [3] in a row (Fig. 20)
Once the system has stopped, hold down this key for 10 seconds. The system will indicate that it has entered TEST MODE and all the leds
will light up for one second. When the system is in TEST MODE, the polarity leds "cleaning" [5] blink.
Fig. 18
Fig. 19
Fig. 20
11