Storage
EP250 should be used by; see packing; at ambient temperature and without
exposure to the sun, the individual components may be kept for 1 year, at
least.
6
Technical characteristics
Modulus of elasticity:
Thermal stability for SG installations:
for zero−point related measurements:
for non zero−point related measurements:
The upper temperature limit for measuring with EP 250 adhesive depends on
the curing procedure chosen. (Please observe the temperature limits of the
strain gages used.)
A1659-1.0 en/de/fr
approx. 2800 N/mm
−240 °C...+ 250 °C
[−400 °F...+ 482 °F]
−240 °C...+ 315 °C
[−400 °F...+ 599 °F]