Accessories; Portable Appliance Test (Pat) Guidelines - ETC CE Source Four Zoom Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
4. Dampen a clean, lint-free cloth with alcohol or distilled water.
(Alcohol is recommended.)
5. Gently wipe the reflector.
6. Insert the barrel into the reflector housing with the pattern slot
on top. (Line up the triangles on both parts.)
7. Pressing in gently, rotate the barrel 45° clockwise until it
settles into position. Rotate the barrel anticlockwise 45°. The
barrel should be firmly attached and the triangles should line
up again.
8. Replace the barrel rotation knob and tighten the bolt.

Accessories

Pattern holder, A-size
Pattern holder, B-size
Pattern holder, glass
190 mm (7 .50") snoot for Zoom
190 mm (7 .50") colour frame for Zoom
Drop-in iris assembly
30" (76.2cm) safety cable, black
Gel frame holder extender for Zoom
190 mm (7 .50") x 70 mm Aperture donut

Portable Appliance Test (PAT) Guidelines

The Portable Appliance Test is a set of tests that must be
administered to electrical equipment in the UK and some
locations in Europe to ensure safety.
The tests are typically carried out using a small PAT device. The
PAT device connects to a power source and then attaches to the
product via an electrical outlet and test probes. The PAT provides
a simple pass or fail result, allowing rapid testing of large
inventories.
The following guidelines provide instructions for applying the PAT
to the Source Four Zoom.
Testing New Luminaires
Source Four Zoom luminaires include a specific PAT point where
the test clip is attached, as shown in the Figure 12 . The PAT test
is comprised of two tests: the ground test and the insulation test.
14 • CE Source Four Zoom
400PH-A
400PH-B
400PH-G
400PTH6
407CF
400RS
400SC
400PGE3
400ZDN
PAT point
Figure 12