Wiring and power information
A plug of at least 2.5 amp (220/240V) rating should be attached to
the luminaire's mains lead. The wires in the mains lead are
2
1.5mm
each and coloured in accordance with the following code:
Green and Yellow:
Blue:
Brown:
WARNING! This luminaire must be earthed.
Current rating:
Operating frequency:
HPL lamps
HPL lamps are tungsten halogen lamps.
Important: Verify that the HPL lamp you use is suitable for the
voltage at your facility. 115-, 120-, 230-, and 240-volt HPL lamps
are available. Operating HPL lamps above their rated voltage
reduces lamp life and can cause premature lamp failure.
WARNING! Do not use lamps other than the HPL in CE
Source Four Zoom luminaires. Use of lamps other than HPL
will void CE safety conformity and warranty.
Lamp code
HPL 575/230
HPL 575/230X 575
HPL 575/240
HPL 575/240X 575
HPL 550/77
HPL 550/77X
HPL 575/115
HPL 575/115X
HPL 575/120
8 • CE Source Four Zoom
Earth
Neutral
t 180°c
Live
120V/5 amp maximum
240V/2.5 amp maximum
50/60Hz
Watts Volts
Color temp Ave rated life
575
230
3,200ºK
230
3,050ºK
575
240
3,200ºK
240
3,050ºK
550
77
3,250ºK
550
77
3,050ºK
575
115
3,250ºK
575
115
3,050ºK
575
120
3,250ºK
400 hour
1500 hour
400 hours
1500 hour
300 hour
2,000 hour
300 hour
1,000 hour
300 hour